SoliTek SOLID Series Solar Modules

वापर सूचना
- Read this guide entirely before installation.
- This document provides minimum requirements and recommendations for safe and successful installation of SoliTek PV modules and is necessary to retain compliance with IEC 61215, IEC 61730, and UL 61730 standards.
- This guide provides basic information on JSC SoliTek Cells SOLID series photovoltaic modules, including their installation and safe handling.
- All instructions should be read and understood before attempting installation. Contact your dealer or JSC SoliTek Cells for further information if needed.
- This documentation refers to the PV modules themselves and is not a comprehensive installation manual for personnel not specifically trained in PV modules.
- It serves as a general but strictly mandatory reference for the installer. Infringement or inaccurate observance of any clause in this documentation voids the warranty.
- The installer must understand and follow all applicable local, state, and federal regulations and standards for building construction, electrical design, fire, and safety.
- Check with local authorities for permitting requirements before installing or maintaining PV modules, and become familiar with mechanical and electrical requirements for photovoltaic systems.
- या मार्गदर्शकातील सूचनांचे पालन करण्यात अयशस्वी झाल्यास सिस्टम घटकांचे नुकसान होऊ शकते, कर्मचारी धोक्यात येऊ शकतात, मालमत्तेचे नुकसान होऊ शकते किंवा पॅनेल वॉरंटी अवैध होऊ शकते.
- Rooftop PV systems should only be installed on dwellings formally analyzed for structural integrity and confirmed to be capable of handling the additional weighted load of PV system components (including PV modules) by a certified building specialist or engineer.
सामान्य आवश्यकता
- कृपया स्थापनेपूर्वी हे मार्गदर्शक पूर्णपणे वाचा.
- या दस्तऐवजाचा उद्देश SoliTek PV मॉड्यूल्सच्या सुरक्षित आणि यशस्वी स्थापनेसाठी किमान आवश्यकता आणि शिफारसी प्रदान करणे आहे.
- या दस्तऐवजात IEC 61215, IEC 61730, UL 61730 मानकांचे पालन करण्यासाठी SoliTek PV मॉड्यूलचे पालन राखण्यासाठी आवश्यक असलेल्या आवश्यकता देखील आहेत.
- या मार्गदर्शकामध्ये JSC “SoliTek Cells” SOLID मालिका फोटोव्होल्टेइक मॉड्युल्स, त्यांची स्थापना आणि सुरक्षित हाताळणी यासंबंधी मूलभूत माहिती आहे. इंस्टॉलेशनचा प्रयत्न करण्यापूर्वी सर्व सूचना वाचल्या आणि समजून घेतल्या पाहिजेत. काही प्रश्न असल्यास, अधिक माहितीसाठी कृपया तुमच्या डीलरशी किंवा JSC “SoliTek Cells” शी संपर्क साधा.
- This documentation refers to the PV-modules themselves and is not meant to be a complete installation manual for personnel not specifically trained to PV-modules.
- It serves as a general but strictly mandatory reference for the Installer.
- या दस्तऐवजीकरणातील कोणत्याही कलमाचे उल्लंघन किंवा चुकीचे पालन केल्यास वॉरंटी रद्द होते.
- इंस्टॉलरने इमारत बांधकाम, इलेक्ट्रिकल डिझाइन, अग्नि आणि सुरक्षिततेसाठी सर्व लागू स्थानिक, राज्य आणि फेडरल नियम आणि मानके समजून घेणे आणि त्यांचे पालन करणे आवश्यक आहे आणि PV मॉड्यूल स्थापित करण्याचा किंवा देखरेख करण्याचा प्रयत्न करण्यापूर्वी लागू परवानगी आवश्यकता निश्चित करण्यासाठी स्थानिक अधिकार्यांकडून तपासणे आवश्यक आहे आणि फोटोव्होल्टेइक सिस्टमसाठी यांत्रिक आणि विद्युत आवश्यकतांशी परिचित व्हा.
- या मार्गदर्शकातील सूचनांचे पालन करण्यात अयशस्वी झाल्यास सिस्टम घटकांचे नुकसान होऊ शकते, कर्मचारी धोक्यात येऊ शकतात, मालमत्तेचे नुकसान होऊ शकते किंवा पॅनेलची वॉरंटी अवैध होऊ शकते.
- रूफटॉप पीव्ही सिस्टीम फक्त अशा निवासस्थानांवर स्थापित केल्या पाहिजेत ज्यांचे संरचनात्मक अखंडतेसाठी औपचारिकपणे विश्लेषण केले गेले आहे आणि प्रमाणित इमारत तज्ञ किंवा अभियंत्याद्वारे पीव्ही मॉड्यूल्ससह, पीव्ही सिस्टम घटकांचे अतिरिक्त भारित भार हाताळण्यास सक्षम असल्याची पुष्टी केली गेली आहे.
- For your safety, do not attempt to work on a rooftop until safety precautions have been identified and taken, including, without limitation fall protection measures, ladders or stairways, and personal protective equipment (PPE).
- For your safety, do not install or handle PV modules under adverse conditions, including, without limitation strong or gusty winds, and wet or frosted roof surfaces.
- फ्लॅट-प्लेट पीव्ही मॉड्यूलच्या बांधकामामध्ये दोन काचेच्या शीटमध्ये इन्सुलेट सामग्रीमध्ये अंतर्भूत केलेल्या सौर पेशींचे लॅमिनेटेड असेंब्ली असते.
- भविष्यातील संदर्भासाठी हे दस्तऐवज सुरक्षित ठिकाणी ठेवा.
- मॉड्यूल वेगळे करण्याचा प्रयत्न करू नका आणि कोणतीही संलग्न नेमप्लेट किंवा घटक काढू नका! असे केल्याने वॉरंटी रद्द होईल.
हाताळणी आणि अनुप्रयोग
हाताळणी
- SoliTek PV modules must be transported in the supplied packaging only and kept in the packaging until they are ready to be installed.
- Protect pallets against movement and exposure to damage during transportation. Secure pallets from falling over.
- पॅलेट पॅकेजिंगवर दर्शविल्यानुसार, स्टॅक करण्यासाठी पॅलेटची कमाल उंची ओलांडू नका.
- Store pallets in a cool and dry location until the PV modules are ready to be unpackaged.
- SoliTek PV modules are heavy and should be handled with care. Never use the junction box or cables as a grip.
- Do not exert mechanical stress on the cables.
- Never step on PV modules or drop or place heavy objects on them.
- Be careful when placing PV modules on hard surfaces and secure them from falling.
- Broken glass can result in personal injury. PV modules with broken glass cannot be repaired and must not be used.
- Broken or damaged PV modules must be handled carefully and disposed of properly.
अर्ज
निर्बंध
- SoliTek PV modules must be mounted on appropriate mounting structures positioned on suitable buildings, the ground, or other structures suitable for PV modules (e.g. carports, building facades or PV trackers).
- PV modules must not be mounted on moving vehicles of any kind. Modules must not be installed in locations where they could be submerged in water.
- Do not install modules above 2000 m (6561 ft) altitude above sea level
- सॉलिटेक पीव्ही मॉड्यूल्सवर कृत्रिमरित्या केंद्रित प्रकाश निर्देशित केला जाऊ नये.
शिफारशी
- SoliTek शिफारस करतो की पावसापासून योग्य स्वत: ची साफसफाई करण्यासाठी PV मॉड्यूल किमान 10 अंशांच्या झुकलेल्या कोनात बसवावेत.
- PV मॉड्यूल किंवा मॉड्यूल्सचे आंशिक किंवा पूर्ण शेडिंग सिस्टम कार्यप्रदर्शन लक्षणीयरीत्या कमी करू शकते.
- SoliTek PV मॉड्यूल्सद्वारे उत्पादित ऊर्जेचे प्रमाण वाढवण्यासाठी वर्षभर सावलीचे प्रमाण कमी करण्याची शिफारस करते.
- उच्च प्रणाली खंडtages could be induced in the event of an indirect lightning strike, which could cause damage to PV system components.
- The open area of wire loops should be minimized in order to reduce the risk of lightning-induced voltage surges.
- उत्तम मॉड्यूल वेंटिलेशन आणि लहान कनेक्शन केबल्स विद्युत ऊर्जा उत्पादन वाढवतात.
बायफेशियल मॉड्यूल्ससाठी:
- जमिनीपासून पीव्ही पॅनेलची उंची वाढवण्याची शिफारस केली जाते जेणेकरून अधिक प्रकाश मॉड्यूलच्या खाली प्रवास करू शकेल आणि नंतर परावर्तित होईल.
- पांढऱ्या (उच्च अल्बेडो व्हॅल्यू), प्रकाश-प्रतिबिंबित पृष्ठभागांवर मॉड्यूल स्थापित केले असल्यास बायफेशियल फायदा लक्षणीयरीत्या वाढतो.
विद्युत प्रतिष्ठापन
सुरक्षितता
- पीव्ही मॉड्युल विद्युत प्रवाह आणि व्हॉल्यूम तयार करू शकतातtage कोणत्याही तीव्रतेच्या प्रकाशाच्या संपर्कात असताना. उच्च प्रकाशाच्या तीव्रतेसह विद्युत प्रवाह वाढतो. DC voltage 50 व्होल्ट किंवा त्याहून अधिक संभाव्य प्राणघातक आहे. प्रकाशाखाली कार्यरत असलेल्या PV प्रणालीच्या थेट सर्किटरीशी संपर्क साधल्याने प्राणघातक विद्युत शॉक होऊ शकतो.
- पीव्ही मॉड्यूल्सना पूर्णपणे प्रकाशापासून काढून टाकून किंवा त्यांच्या पुढील पृष्ठभागावर अपारदर्शक पदार्थाने झाकून ऊर्जा कमी करा. कोणत्याही प्रकाशाच्या संपर्कात येणाऱ्या मॉड्यूल्ससह काम करताना लाईव्ह इलेक्ट्रिकल उपकरणांसाठी सुरक्षा नियमांबाबत. पीव्ही मॉड्यूल्ससह काम करताना इन्सुलेटेड टूल्स वापरा आणि धातूचे दागिने घालू नका.
- आर्किंग आणि इलेक्ट्रिकल शॉक टाळण्यासाठी, लोडखाली विद्युत कनेक्शन डिस्कनेक्ट करू नका. सदोष कनेक्शनमुळे आर्किंग आणि इलेक्ट्रिकल शॉक देखील होऊ शकतो. कनेक्टर कोरडे आणि स्वच्छ ठेवा आणि ते योग्यरित्या कार्यरत स्थितीत असल्याची खात्री करा. इलेक्ट्रिकल कनेक्शन सुरक्षित करण्यासाठी कधीही कनेक्टरमध्ये धातूच्या वस्तू घालू नका किंवा त्यामध्ये कोणत्याही प्रकारे बदल करू नका.
- Do not touch or handle PV modules with broken glass unless the PV modules are first disconnected, and you are wearing proper PPE. Avoid handling PV modules when they are wet unless cleaning the PV modules as directed in this manual. Never touch electrical and wet connections without protecting yourself with insulated gloves.
- The modules are qualified for Class II protection against electrical shock, in accordance with clause 4 of IEC 61730-1:2016, which can be used in systems operating at > 50 V DC or >240 W, where general contact access is anticipated and modules qualified for safety through UL 61730 within this application class are considered to meet the requirements of Safety Class II.
- सौर फोटोव्होल्टेइक प्रणाली स्थापित करण्यासाठी विशेष कौशल्ये आणि ज्ञान आवश्यक आहे. हे केवळ पात्र आणि विशेष निर्देशित कर्मचार्यांनीच केले पाहिजे. इंस्टॉलर इलेक्ट्रिक शॉकच्या जोखमीसह इजा होण्याचा सर्व धोका गृहीत धरतो.
- विशेषत: फोटोव्होल्टेइक प्रणालीमध्ये वापरण्यासाठी डिझाइन केलेली उपकरणे, कनेक्टर, वायरिंग आणि माउंटिंग हार्डवेअर वापरा.
- Before any manipulation at an installed PV plant, switch it off first on the AC-side, and then on the DC side of the inverter or the charge controller.
- प्रकाशाच्या संपर्कात असलेल्या फोटोव्होल्टेइक मॉड्यूलशी जोडलेल्या तारा डिस्कनेक्ट करताना, विद्युत चाप येऊ शकतो. आर्क्स जळू शकतात, आग लागू शकतात किंवा अन्यथा सुरक्षितता (प्राणघातक इलेक्ट्रिक शॉक पर्यंत) समस्या निर्माण करू शकतात.
- उर्वरित व्हॉल्यूम तपासाtage before starting and observe the local safety-relevant regulations for such working conditions.
- सामान्य परिस्थितीत, फोटोव्होल्टेइक मॉड्यूल अधिक वर्तमान आणि/किंवा व्हॉल्यूम तयार करू शकतोtage (येथे: 30V DC) मानक चाचणी परिस्थितीत नोंदवल्यापेक्षा.
- डीसी व्हॉल्यूमशी संपर्क साधाtage 30 V किंवा त्याहून अधिक संभाव्य धोकादायक आहे. सूर्यप्रकाशाच्या संपर्कात असलेले मॉड्यूल वायरिंग किंवा हाताळताना सावधगिरी बाळगा.
- मालिकेतील समान रेट केलेल्या आउटपुट करंटसह फक्त मॉड्यूल कनेक्ट करा. मॉड्युल्स मालिकेत जोडलेले असल्यास, एकूण व्हॉल्यूमtage हे वैयक्तिक मॉड्यूल व्हॉल्यूमच्या बेरजेइतके आहेtages
- फक्त त्याच व्हॉल्यूमसह मॉड्यूल किंवा मॉड्यूलचे मालिका संयोजन कनेक्ट कराtage in parallel. If modules are connected in parallel, the total current is equal to the sum of the individual module or series combination currents.
- विशिष्ट फोटोव्होल्टेईक सिस्टममध्ये नेहमीच प्रकारचे मॉड्यूल वापरा.
- If the sum of short circuit currents of the parallel-connected modules exceeds the reverse current, string diodes or fuses have to be used in each string of modules connected in parallel. These string diodes or fuses have to be qualified for the maximum expected current and voltage. The fuse rating value is also corresponds to the maximum reverse current that a module can withstand. The reverse current value can be found on the product label, in the product datasheet or in chapter 8 of the installation manual. Observe the instructions and safety precautions for all other components used in the system, including wiring and cables, connectors, DC-breakers, inverters, etc.
- विद्युत प्रतिष्ठापनांवर वापरण्यासाठी मंजूर केलेली योग्य सुरक्षा उपकरणे (इन्सुलेटेड साधने, डायलेक्ट्रिक हातमोजे, शूज आणि इ.) वापरा.
कॉन्फिगरेशन
- सामान्य परिस्थितीत, फोटोव्होल्टेइक मॉड्यूलला अधिक वर्तमान आणि/किंवा व्हॉल्यूम निर्माण करणार्या परिस्थितीचा अनुभव येण्याची शक्यता असतेtage than reported at Standard Test Conditions (STC: 1000 W/ m2, AM 1.5, and 250C/770F cell temperature) or Bifacial nominal power index(BNPl front irradiance 1000 W/m2, back irradiance 135 W/m2 AM 1.5, and 25 OC/770F cell temperature). The short-circuit current (ISC) should be multiplied by a factor of 1.25 and the open-circuit voltagघटक व्हॉल्यूम निर्धारित करताना इंस्टॉलेशन स्थानासाठी नोंदलेल्या सर्वात कमी आणि सर्वोच्च वातावरणीय तापमानाच्या आधारावर e (VOC) चा 1.25 पर्यंत गुणाकार केला पाहिजे.tage रेटिंग, कंडक्टर वर्तमान रेटिंग, फ्यूज आकार आणि PV आउटपुटशी कनेक्ट केलेल्या नियंत्रणांचा आकार.
- खंडtagजेव्हा PV मॉड्युल्स थेट मालिकेत जोडलेले असतात तेव्हा es additive असतात आणि PV मॉड्युल्स थेट समांतर जोडलेले असतात तेव्हा मॉड्युल करंट अॅडिटीव्ह असतात. विविध विद्युत वैशिष्ट्यांसह पीव्ही मॉड्यूल थेट मालिकेत जोडलेले नसावेत. PV मॉड्युलशी जोडलेल्या योग्य तृतीय-पक्ष इलेक्ट्रॉनिक उपकरणांचा वापर भिन्न विद्युत कनेक्शन सक्षम करू शकतो आणि निर्मात्याच्या निर्दिष्ट निर्देशांनुसार स्थापित करणे आवश्यक आहे.
- कमाल खंडtage of serial interconnection of the modules must be less than the maximum certified module’s system voltage तसेच, कमाल इनपुट व्हॉल्यूमtagइन्व्हर्टर आणि सिस्टममधील इतर इलेक्ट्रिकल उपकरणांचा e विचारात घेणे आवश्यक आहे. ओपन सर्किट व्हॉल्यूमtage of the array string needs to be calculated at the lowest expected a mbient temperature forthe location. The maximal system voltage for the module is indicated in the module’s datasheet.
- Accordingly, for BLACKSTAR, SOLID or MAGNUS series modules, the values of ISC and VOC under STC or BNPI marked on this module should be multiplied by a factor of 1,25 when determining component voltage ratings, conductor current ratings, fuse sizes, and size of controls connected to the PV output. In the USA, referto Section 690-8 of the National Electrical Code (N EC) for an additional multiplying factor of 125 percent (80 percent de-rating) which may be applicable.
ओव्हरकरंट प्रोटेक्शन डिव्हाइस (ओसीपीडी)
- When the potential reverse current of a PV string exceeds the rated SoliTek PV module series fuse rating (values indicated at the module datasheet) an overcurrent protection device (OCPD) must be used.
- An overcurrent protection device is required for each series string if more than two series are connected in parallel.
- In this case, it is needed to use one fuse per string rated at 1.25 x Isc or higher (Isc is the PV module’s short circuit current at STC). A PV fuse on each PV string will protect the PV modules and conductors from overcurrent faults and help minimize any safety hazards.
- The PV fuse will also isolate the faulted PV string so the balance of the PV system can continue to generate electricity.
- फ्यूज amp रेटिंग ≥ 1.25 x Isc
- उपलब्ध पीव्ही फ्यूजच्या कॅटलॉगवर पुढील उच्च मानक रेटिंग निवडा.
- Isc = मानक चाचणी परिस्थिती (STC) वर एका मॉड्यूलचा शॉर्ट-सर्किट प्रवाह.
- Isc ऑफ SoliTek मॉड्युल्सची मूल्ये विचारात घेतल्यास, PV फ्यूजचे इंस्टॉलेशनमध्ये वापरायचे योग्य मूल्य 30 A आहे. SoliTek सकारात्मक आणि नकारात्मक दोन्ही कंडक्टरमध्ये PV फ्यूज वापरण्याची शिफारस करते.
केबल आणि वायरिंग
SoliTek PV मॉड्यूल दोन मानक, सूर्यप्रकाश-प्रतिरोधक आउटपुट केबल्ससह प्रदान केले जातात जे बहुतेक स्थापनेसाठी तयार असलेल्या PV कनेक्टरसह समाप्त केले जातात. सकारात्मक (+) टर्मिनलमध्ये पुरुष कनेक्टर आहे तर नकारात्मक (-) टर्मिनलमध्ये महिला कनेक्टर आहे. मॉड्यूल वायरिंग हे मालिका कनेक्शनसाठी (म्हणजे, पुरुष (+) ते महिला (-) इंटरकनेक्शन्ससाठी आहे, परंतु निर्मात्याच्या सूचनांचे पालन करेपर्यंत पर्यायी वायरिंग कॉन्फिगरेशन असलेल्या योग्य तृतीय-पक्ष विद्युत उपकरणांना जोडण्यासाठी देखील वापरले जाऊ शकते.
PV मॉड्युलच्या जास्तीत जास्त शॉर्ट-सर्किट करंटवर वापरण्यासाठी मंजूर असलेल्या योग्य क्रॉस-सेक्शनल क्षेत्रांसह फील्ड वायरिंग वापरा. सर्व वायरिंग दुहेरी इन्सुलेटेड, क्रॉस-लिंक केलेल्या केबल्स किमान 1,8 केव्ही (1500 व्ही व्हॉल्यूमपेक्षा जास्त) असणे आवश्यक आहेtage) आणि किमान रेट केलेले तापमान 90 ˚C (190 °F). वायरचा आकार 4 मिमी² (12 AWG) पेक्षा कमी नाही. इन्सुलेशन प्रकार वापरलेल्या इंस्टॉलेशन पद्धतीच्या प्रकारासाठी योग्य असावा आणि IEC 61730 आणि सुरक्षा वर्ग II आवश्यकता पूर्ण करणे आवश्यक आहे.
- इन्सुलेशन पातळी: 1,8 केव्ही (कंडक्टर-कंडक्टर).
- तापमान: -40°C पर्यंत +90°C (-40°F ते 190°F पर्यंत) किमान.
- कंडक्टरचे बांधकाम: तांब्याची शुद्धता 99,9% पेक्षा जास्त असलेली टिन केलेली तांब्याची तार.
- प्राथमिक इन्सुलेशन: क्रॉस-लिंक्ड पॉलीथिलीन (XLPE), सूर्यप्रकाश आणि आर्द्रता प्रतिरोधक, ज्योत प्रतिरोधक. भूमिगत स्थापित नळ आणि रेसवेसाठी योग्य.
- इन्सुलेशन (जॅकेट): थर्मोप्लास्टिक, सूर्यप्रकाश प्रतिरोधक, ज्योत प्रतिरोधक, पाणी प्रतिरोधक.
- इन्सुलेशनसह किमान केबल बाह्य व्यास – 5,2 मिमी (2,05 इंच).
- किमान कंडक्टर क्रॉस-सेक्शन - 4 मिमी² (12 AWG).
SoliTek शिफारस करतो की इंस्टॉलर्सने PV सिस्टीममध्ये डायरेक्ट करंट (DC) वायरिंगसाठी पात्र असलेल्या फक्त सूर्यप्रकाश-प्रतिरोधक केबल्स वापरा. केबल्स माउंटिंग स्ट्रक्चरमध्ये अशा प्रकारे निश्चित केल्या पाहिजेत की केबल आणि/किंवा मॉड्यूलचे यांत्रिक नुकसान टाळले जाईल. केबल्सवर ताण लागू करू नका. फिक्सिंगसाठी, सूर्यप्रकाश-प्रतिरोधक केबल टाय आणि/किंवा वायर मॅनेजमेंट क्लिप यासारखी योग्य साधने वापरा. केबल्स सूर्यप्रकाश प्रतिरोधक आणि जलरोधक असताना, शक्य असेल तिथे थेट सूर्यप्रकाश आणि केबल्स पाण्यात बुडवणे टाळा.
जंक्शन बॉक्समधील केबल्सची मानक लांबी १.२ मीटर (४७.२४ इंच) आहे. सिस्टममध्ये दोन पॅनेल एकमेकांशी जोडले जातील असा हेतू आहे.
वाढत आहे
- Module grounding must be done in accordance with the electrical design and construction specifications, procedures, regulations and other special grounding requirements applicable to the installation sites. If grounding is needed, it should be done accordingly:
Framed type modules grounding
फ्रेमवर ग्राउंडिंग चिन्हासह चिन्हांकित केलेले छिद्र केवळ ग्राउंडिंगसाठी वापरले जाऊ शकतात. मॉड्यूल फ्रेमवर अतिरिक्त ग्राउंडिंग होल ड्रिल करू नका.
The grounding conductor or strap may be copper, copper alloy, or any other material acceptable foruse as an electrical conductor in accordance with local electric codes and regulations.
त्यानंतर ग्राउंडिंग कंडक्टरने योग्य अर्थ ग्राउंड इलेक्ट्रोड वापरून पृथ्वीशी कनेक्शन बनवावे.
A bolted connection is required; it incorporates:
- M4 चा बोल्ट आकार.
- बोल्ट हेडखालील टूथ वॉशर किंवा सेरेटेड बोल्टने एनोडाइज्ड फ्रेमसारख्या नॉनकंडक्टिव्ह कोटिंग्जमध्ये प्रवेश केला पाहिजे.
- M4 बोल्टसाठी योग्य असलेला फास्टन नट.
- सर्व हार्डवेअर नॉनफेरस मेटल, 300-सिरीज स्टेनलेस स्टील किंवा योग्यरित्या गंज-संरक्षित असावेत.
- नट लॉक करण्याचा शिफारस केलेला टॉर्क 2 Nm÷2.2 Nm (1,48÷1,62 ft-lb) आहे.
- ग्राउंडिंग बोल्टला सर्व कनेक्टिंग घटकांमधून जावे लागते.

- PV मॉड्यूल्सच्या मेटॅलिक फ्रेम्सच्या ग्राउंडिंगसाठी सूचीबद्ध केलेल्या आणि ओळखल्या गेलेल्या डिव्हाइसेसना मॉड्यूलच्या उघड झालेल्या मेटॅलिक फ्रेमला ग्राउंड माउंटिंग स्ट्रक्चर्समध्ये ग्राउंड करण्याची परवानगी आहे.
- In any case the grounding screws or other parts have to be used separately from the mounting parts of the module.
- Alternate grounding options built through the mounting system are acceptable as long as they have been IEC and UL approved.
- Grounding resistance of the grounding structure shall be reached according to local regulations, Eurocodes, or other legal normative references.
Frameless type modules grounding
- Due to that modules are without frame, grounding is not forseen. Other PV plant equipment should be grounded according to the local and national electrical codes.
कनेक्टर
- Connectors for SoliTek PV panels are Stäubli MC4-Evo 2. Keep connectors dry and clean and ensure that connector caps are hand-tight before connecting the modules.
- ओले, मातीचे किंवा अन्यथा सदोष कनेक्टरसह विद्युत कनेक्शन करण्याचा प्रयत्न करू नका.
- कनेक्टर्सना सूर्यप्रकाशात येण्यापासून आणि पाण्यात बुडवून ठेवण्यापासून टाळा. कनेक्टर्स जमिनीवर किंवा छताच्या पृष्ठभागावर बसवण्याचे टाळा.
- Do not disconnect under load. Faulty connections can result in arcs and electrical shock.
- सर्व विद्युत कनेक्शन सुरक्षितपणे जोडलेले आहेत का ते तपासा. सर्व लॉकिंग कनेक्टर पूर्णपणे गुंतलेले आणि लॉक केलेले असल्याची खात्री करा.
बायपास डायोड्स
The PV module’s junction box contains 3 bypass diodes (one in each part of split junction box; Schottky type) connected in parallel with the PV cell strings. In the case of partial shading (hot-spot effect), the diodes bypass the current generated by the non-shaded cells, therebylimiting module heating and performance losses.
बायपास डायोड हे अतिप्रवाह संरक्षण साधने नाहीत. बायपास डायोड आंशिक छायांकन झाल्यास सेल स्ट्रिंगमधून विद्युत् प्रवाह वळवतात. या डायोडची वैशिष्ट्ये:
- खंडtagई रेटिंग - 50 व्ही.
- वर्तमान रेटिंग - 25 ए.
फायर क्लास रेटिंग
- SoliTek SOLID बायफेशियल आणि ब्लॅकस्टार मॉड्यूल्सना IEC अग्नि चाचणीने मान्यता दिली आहे आणि त्यांनी ज्वलनशीलता वर्ग A प्राप्त केला आहे. IEC 127-5 च्या बिंदू A.300 मध्ये नमूद केल्याप्रमाणे, 11,81 मिमी (2.5 इंच) प्रति 61730 मिमी (2 इंच) च्या झुकाववर अग्नि चाचणी घेण्यात आली.
- SoliTek SOLID Bifacial has fire rating of 28 according to UL1703-2 standard. SoliTek Blackstar has fire rating of 29 according to UL1703-2 standard.
यांत्रिक माउंटिंग
- The mechanical loads described in this manual are the test loads.
- For calculating the equivalent maximum design loads, a safety factor of 1.5 (Design load×1.5 safety factor=Mechanical test load) needs to be considered in compliance with the requirements of the local laws and regulations.
सामान्य आवश्यकता
- Modules can be mounted in landscape or portrait orientation. For the bifacial modules, in order to get notable bifacial gain, the distance between the bottom of the modules and the roof or ground surface shall be at least 0,8 m (31,50 inch).
- Also, the bifacial gain increases significantly if modules are installed above white, light-reflecting surfaces (under surfaces with high albedo value).
- If the mounting rails are installed across the module, the bifaciality effect will be lower due to back-side cells shading.
- कृपया माउंटिंग सिस्टममध्ये समाविष्ट असलेल्या सुरक्षा नियमांचे आणि इंस्टॉलेशन सूचनांचे निरीक्षण करा. आवश्यक असल्यास, कृपया अधिक माहितीसाठी थेट पुरवठादाराशी संपर्क साधा.
- The modules must be safely set onto the mounting rail.
- The whole rail supporting the photovoltaic system must be strong enough to resist potential mechanical pressures caused either by wind or snow, in accordance with local, regional and state safety (and other associated) standards.
- The mounting system shall be tested and inspected by a third-party testing institution with static mechanical analysis capacity in accordance with local national standards or international standards.
- Before installing modules on a roof, ensure that the roof construction is suitable.
- In addition, any roof penetration required to mount the modules must be properly sealed to prevent leaks.
- माउंटिंग रेल थर्मल विस्ताराच्या परिणामी विस्तारते तेव्हा मॉड्यूल्स विकृत किंवा प्रभावित होणार नाही याची खात्री करा.
- The module can appear thermal expansion and cold contraction; thus, the interval between two adjoining modules shall be no lesser than 10 mm (0,39 inch).
- काचेच्या पृष्ठभागावर आणि मॉड्यूल्सच्या फ्रेममध्ये छिद्र पाडण्याचा प्रयत्न करू नका कारण यामुळे वॉरंटी रद्द होईल.
- The mounting method must not result in the direct contact of dissimilar metals with the aluminum frame of the modules that will result in galvanic corrosion.
माउंटिंग घटक टिकाऊ, गंजरोधक आणि अतिनील-प्रतिरोधक पदार्थांपासून बनलेले असले पाहिजेत (स्टेनलेस स्टील आणि अॅनोडाइज्ड अॅल्युमिनियम घटकांची शिफारस केली जाते).
सीएल सह माउंटिंगAMPS
- किमान 4 लॅमिनेट cl वापराampमाउंटिंग रेलवर मॉड्यूल्स निश्चित करण्यासाठी s. मॉड्यूल्स clamps धातूचे भाग पुढील किंवा मागील काचेच्या संपर्कात येऊ नयेत. या प्रकारची निवड करताना सी.एलamp- माउंटिंग पद्धत, किमान चार सीएल वापराampप्रत्येक मॉड्यूलवर s; दोन clamps प्रत्येक लांब बाजूला संलग्न केले पाहिजे. स्थानिक वारा आणि बर्फाच्या भारांवर अवलंबून, अतिरिक्त clampमॉड्यूल भार सहन करू शकतील याची खात्री करण्यासाठी s ची आवश्यकता असू शकते.
- Clamps कडक टॉर्क किमान १५ Nm (११.०६ फूट-lb) असावा, परंतु २० Nm (१४.७५ फूट-lb) पेक्षा जास्त नसावा. सहसा, १५ Nm (११.०६ फूट-lb) गाठले जाते जेव्हा दोन अॅल्युमिनियम प्रोfileएकमेकांना स्पर्श करा. ४५° पेक्षा जास्त उतार असलेल्या खड्ड्याच्या छतावर पोर्ट्रेट ओरिएंटेशनमध्ये मॉड्यूल स्थापित केले जाते तेव्हा मॉड्यूलच्या तळाशी अतिरिक्त हुक आवश्यक असतो.

SOLID Black, Semi-clear, Satin, Agro Frameless
ट्रान्सव्हर्सल रेलसह


BLACKSTAR, SOLID Black 35(40) mm, SOLID Semi-clear 35(40) mm, SOLID Satin 35(40) mm, SOLID Agro 35(40) mm, Magnus Framed mounting
- या प्रकारची निवड करताना सी.एलamp- माउंटिंग पद्धत, किमान चार सीएल वापराampप्रत्येक मॉड्यूलवर s; दोन clampमॉड्यूलच्या प्रत्येक बाजूला s जोडले पाहिजेत. मॉड्यूल clamps समोरच्या काचेच्या संपर्कात येऊ नये आणि फ्रेम विकृत होऊ नये.
- मॉड्यूल cl मधून सौर पेशींवर सावलीचा प्रभाव टाळण्याची खात्री कराamps.
- The module frame is not to be modified under any circumstances. Do not to block the drain hole of the frame.
- cl ची लांबीamp should be at least 30 mm (1,18 inch).
- क्लamp मॉड्यूल फ्रेमला किमान 5 मिमी (0,2 इंच) ने ओव्हरलॅप करणे आवश्यक आहे, परंतु 10 मिमी (0,4 इंच) पेक्षा जास्त नाही.
ट्रान्सव्हर्सल रेलसह

ट्रान्सव्हर्सलशिवाय रेल किंवा रेल लांब बाजूच्या फ्रेमला लंब असतात

इन्सर्शन सिस्टमसह

बोल्ट सह माउंटिंग
- ट्रान्सव्हर्सल बारवरील दर्शविलेल्या माउंटिंग होलमधून मॉड्यूल चार M8 स्टेनलेस स्टील बोल्टने जोडलेले आणि आधारलेले असले पाहिजे. cl वर टॉर्कamp bolt has to be in range of 8÷10 Nm (5,9÷7,38 ft-lb). The transversal bars positioning is shown in Figure 3.
- If additional mounting points are required, depending on the local wind and snow loads, then a mounting solution with clamping हार्डवेअर निवडणे आवश्यक आहे.

- Mounting with bolts can be done only through dedicated predrilled holes in the frame.
- नवीन छिद्र पाडणे निषिद्ध आहे आणि वॉरंटी रद्द करेल.

जंक्शन बॉक्सची स्थिती
- जंक्शन बॉक्स आणि मॉड्यूलच्या काठामधील अंतर किंवा जंक्शन बॉक्सची स्थिती आणि क्षेत्रफळांच्या इतर परिमाणांसाठी कृपया खाली दर्शविलेल्या आकृत्या पहा.

देखभाल
- इष्टतम मॉड्यूल कार्यप्रदर्शन सुनिश्चित करण्यासाठी, SoliTek खालील शिफारस करतो:
- आवश्यक असल्यास, मॉड्यूलच्या समोरील काचेचे पाणी आणि मऊ स्पंज किंवा कापडाने स्वच्छ केले जाऊ शकते.
- अधिक हट्टी डाग काढून टाकण्यासाठी सौम्य, अपघर्षक डिटर्जंटचा वापर केला जाऊ शकतो.
- विद्युत आणि यांत्रिक कनेक्शन वेळोवेळी तपासा आणि ते स्वच्छ, सुरक्षित, पूर्ण आणि सुरक्षित असल्याची खात्री करा.
- समस्या उद्भवल्यास, परवानाधारक/पात्र व्यक्तीचा सल्ला घ्या.
तपशील
| पॅरामीटर \ मॉडेल | ब्लॅकस्टार B.96 | SOLID Black (Semi-Clear) B.96 35(40) mm | ब्लॅकस्टार Satin B.96 | मॅग्नस B.108 |
| चाचणी अटी | STC | STC | STC | STC |
| नाममात्र शक्ती | 455 प | 455 प | 445 प | 510 प |
| इलेक्ट्रिकल डेटा @STC | ||||
| कमाल शक्ती (Pmax), डब्ल्यू | 455 | 455 | 445 | 510 |
| खंडtage कमाल पॉवर (Vmpp) वर, व्ही | 29,71 | 29,71 | 29,40 | 33,34 |
| कमाल शक्ती (Impp) येथे वर्तमान, ए | 15,31 | 15,31 | 15,14 | 15,30 |
| ओपन सर्किट व्हॉल्यूमtage (Voc), व्ही | 34,82 | 34,82 | 34,40 | 39,06 |
| शॉर्ट सर्किट करंट (आयएससी), ए | 15,97 | 15,97 | 15,79 | 15,95 |
| थर्मल डेटा | ||||
| ऑपरेटिंग तापमान श्रेणी | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) |
| Pmax चे तापमान गुणांक | -0,362%/°C (°F) | -0,362%/°C (°F) | -0,362%/°C (°F) | -0,362%/°C (°F) |
| Voc चे तापमान गुणांक | -0,265%/°C (°F) | -0,265%/°C (°F) | -0,265%/°C (°F) | -0,265%/°C (°F) |
| Isc चे तापमान गुणांक | +0,036% /° C (°F) | +0,036% /° C (°F) | +0,036% /° C (°F) | +0,036% /° C (°F) |
| आकार आणि वजन डेटा | ||||
| लांबी | 1762 मिमी | 1762 मिमी | 1762 मिमी | 1961 मिमी |
| रुंदी | 1134 मिमी | 1134 मिमी | 1134 मिमी | 1134 मिमी |
| जाडी | 30 मिमी | 35(40) mm | 30 मिमी | 30 मिमी |
| वजन | 25,5 किलो | 35 (36) किग्रॅ | 25,5 किलो | 28,5 किलो |
| माउंटिंग पद्धत | ||||
| Reference to the chapter | 3.3 | 3.3 | 3.3 | 3.3 |
| इतर | ||||
| कमाल रिव्हर्स करंट, ए | 30 | |||
| Fire class, IEC 61730/UL 61730 | A/प्रकार II | |||
| कमाल प्रणाली खंडtagई, व्ही | 1500 | |||
Table 9. Electrical and mechanical parameters table.
| पॅरामीटर \ मॉडेल | घन Semi- clear B.96 | SOLID Black B.96 | घन Satin B.96 | घन Agro B.64 |
| चाचणी अटी | STC | STC | STC | STC |
| नाममात्र शक्ती | 455 प | 455 प | 445 प | 300 प |
| इलेक्ट्रिकल डेटा @STC | ||||
| कमाल शक्ती (Pmax), डब्ल्यू | 455 | 455 | 445 | 300 |
| खंडtage कमाल पॉवर (Vmpp) वर, व्ही | 29,71 | 29,71 | 29,40 | 19,60 |
| कमाल शक्ती (Impp) येथे वर्तमान, ए | 15,31 | 15,31 | 15,14 | 15,31 |
| ओपन सर्किट व्हॉल्यूमtage (Voc), व्ही | 34,82 | 34,82 | 34,40 | 22,76 |
| शॉर्ट सर्किट करंट (आयएससी), ए | 15,97 | 15,97 | 15,79 | 15,97 |
| थर्मल डेटा | ||||
| ऑपरेटिंग तापमान श्रेणी | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) |
| Pmax चे तापमान गुणांक | -0,30%/°C (°F) | -0,30%/°C (°F) | -0,30%/°C (°F) | -0,30%/°C (°F) |
| Voc चे तापमान गुणांक | -0,25%/°C (°F) | -0,25%/°C (°F) | -0,25%/°C (°F) | -0,25%/°C (°F) |
| Isc चे तापमान गुणांक | +0,045% /° C (°F) | +0,045% /° C (°F) | +0,045% /° C (°F) | +0,045% /° C (°F) |
| आकार आणि वजन डेटा | ||||
| लांबी | 1772 ± 2 मिमी | 1772 ± 2 मिमी | 1772 ± 2 मिमी | 1772 ± 2 मिमी |
| रुंदी | 1144±2 | 1144±2 | 1144 ± 2 मिमी | 1144 ± 2 मिमी |
| जाडी | 7,2 मिमी | 7,2 मिमी | 7,2 मिमी | 7,2 मिमी |
| वजन | 33 किलो | 33 किलो | 33 किलो | 33 किलो |
| माउंटिंग पद्धत | ||||
| Reference to the chapter | 3.2 | 3.2 | 3.2 | 3.2 |
| इतर | ||||
| कमाल रिव्हर्स करंट, ए | 30 | |||
| Fire class, IEC 61730/UL 61730 | A/प्रकार II | |||
| कमाल प्रणाली खंडtagई, व्ही | 1500 | |||
Table 10. Electrical and mechanical parameters table.
| पॅरामीटर \ मॉडेल | SOLID Satin B.96 35 mm | SOLID Satin B. 96 40 मिमी | SOLID AgroB.64 35 mm | SOLID AgroB.64 40 mm |
| चाचणी अटी | STC | STC | STC | STC |
| नाममात्र शक्ती | 445 प | 445 प | 300 प | 300 प |
| इलेक्ट्रिकल डेटा @STC | ||||
| कमाल शक्ती (Pmax), डब्ल्यू | 445 | 445 | 300 | 300 |
| खंडtage कमाल पॉवर (Vmpp) वर, व्ही | 29,40 | 29,40 | 19,60 | 19,60 |
| कमाल शक्ती (Impp) येथे वर्तमान, ए | 15,14 | 15,14 | 15,31 | 15,31 |
| ओपन सर्किट व्हॉल्यूमtage (Voc), व्ही | 34,40 | 34,40 | 22,78 | 22,78 |
| शॉर्ट सर्किट करंट (आयएससी), ए | 15,79 | 15,79 | 15,97 | 15,97 |
| थर्मल डेटा | ||||
| ऑपरेटिंग तापमान श्रेणी | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) |
| Pmax चे तापमान गुणांक | -0,362%/°C (°F) | -0,362%/°C (°F) | -0,30%/°C (°F) | -0,30%/°C (°F) |
| Voc चे तापमान गुणांक | -0,265%/°C (°F) | -0,265%/°C (°F) | -0,25%/°C (°F) | -0,25%/°C (°F) |
| Isc चे तापमान गुणांक | +0,036% /° C (°F) | +0,036% /° C (°F) | +0,045% /° C (°F) | +0,045% /° C (°F) |
| आकार आणि वजन डेटा | ||||
| लांबी | 1762 मिमी | 1762 मिमी | 1762 मिमी | 1762 मिमी |
| रुंदी | 1134 मिमी | 1134 मिमी | 1134 मिमी | 1134 मिमी |
| जाडी | 35 मिमी | 40 मिमी | 35 मिमी | 40 मिमी |
| वजन | 35 किलो | 36 किलो | 35 किलो | 36 किलो |
| माउंटिंग पद्धत | ||||
| Reference to the chapter | 3.3 | |||
| इतर | ||||
| कमाल रिव्हर्स करंट, ए | 30 | |||
| Fire class, IEC 61730/UL 61730 | A/प्रकार II | |||
| कमाल प्रणाली खंडtagई, व्ही | 1500 | |||
Table 11.Electrical and mechanical parameters table.
- The electrical characteristics are within of the indicated values of ISC (φISC) ±3%, VOC (ϕVOC) ±3,5% and PMPP (ϕPmax) ±5%, under Standard Test Conditions (STC) (irradiance of 1000 W/m²,AM 1.5 spectrum, and a cell temperature of 25°C / 77°F)
- सर्व SoliTek SOLID PV पटल विद्युत सुरक्षा वर्ग II शी संबंधित आहेत.
दायित्वाचा अस्वीकरण
- या सूचनेनुसार फोटोव्होल्टेइक प्रणालीची स्थापना, ऑपरेशन, अनुप्रयोग आणि देखभाल नियंत्रित करणे SoliTek साठी अशक्य असल्याने. SoliTek जबाबदारी स्वीकारत नाही आणि अशा इंस्टॉलेशन, ऑपरेशन, वापर किंवा देखरेखीमुळे किंवा कोणत्याही प्रकारे संबंधित कोणत्याही नुकसान, नुकसान किंवा खर्चासाठी दायित्व स्वीकारत नाही.
- SoliTek will not take any responsibility for any possible violation of patent rights and third-party rights that are related to the application of the solar energy system. No permission of patents is given through implication.
- The information of this instruction is from the knowledge and experiences of SoliTek. However, the instructions and suggestions of this instruction do not make an external or internal of guarantee. SoliTek reserves the right to revise this instruction, products and all the information about products without prior notification to customers.
वारंवार विचारले जाणारे प्रश्न
- Q: What should I do before installing the PV modules?
- A: Read this entire guide, understand all instructions, and ensure compliance with all local, state, and federal regulations. Consult a certified building specialist for the structural integrity of the dwelling.
- Q: Can I install the PV modules myself without professional training?
- A: This documentation is not a complete installation manual for personnel not specifically trained in PV-modules. It serves as a general but strictly mandatory reference for the installer. Professional installation is highly recommended.
- Q: What happens if I don’t follow the instructions in this guide?
- A: Failure to follow instructions may damage system components, endanger personnel, damage property, or invalidate the panel warranty.
- Q: Is it safe to work on a rooftop during installation?
- A: Do not attempt to work on a rooftop until safety precautions have been identified and taken, including fall protection measures, ladders or stairways, and personal protective equipment (PPE). Avoid adverse conditions like strong winds or wet/frosted roofs.
- Q: How should I store the PV modules before installation?
- A: Store pallets in a cool and dry location until the PV modules are ready to be unpackaged. Do not exceed the maximum stacking height indicated on the packaging.