📘 Terragene manuals • Free online PDFs
टेराजीन लोगो

Terragene Manuals & User Guides

Terragene provides biotechnology-based infection prevention solutions, including advanced auto-readers and biological indicators for sterilization control.

Tip: include the full model number printed on your Terragene label for the best match.

About Terragene manuals on Manuals.plus

Terragene Sterilization & Infection Control

Terragene is a biotechnology company specializing in infection prevention and sterilization monitoring solutions for healthcare, laboratory, and pharmaceutical environments. Their extensive product lineup includes the Bionova line of Self-Contained Biological Indicators (SCBIs) designed for steam, ethylene oxide, and vaporized hydrogen peroxide sterilization.

Additionally, Terragene manufactures advanced Auto-reader Incubators—such as the Bionova Photon, Hyper (BT98), and IC10/20FR—which offer hyper-rapid readouts to streamline sterile processing workflows. Their physical devices are safely integrated with the Bionova Cloud traceability software and smartphone applications, enabling precise, automated quality control from washing to final sterilization validation.

Terragene Bionova Auto-Readers

To assure proper readouts, Terragene provides purpose-built auto-reader incubators like the Bionova IC10/20FR and Hyper Auto-reader series. These devices guarantee correct temperature regulation and utilize fluorescence techniques to provide accurate sterility confirmation in mere minutes or seconds. Before operating these complex bio-medical devices, it is extremely important to review the correct user manuals for incubation parameters and safety practices.

Terragene manuals

कडून नवीनतम मॅन्युअल manuals+ या ब्रँडसाठी तयार केलेले.

Terragene PCD98 Biological Indicator User Guide

३ जून २०२४
Terragene PCD98 Biological Indicator Introduction Effective sterilization monitoring in healthcare facilities is a critical component of infection prevention programs. For vaporized hydrogen peroxide (VH2O2) sterilization processes, the use of biological…

Terragene BT98 Biological Indicator Instruction Manual

6 मार्च 2026
BT98 Biological Indicator R04 / 08.2025 Hyper Rapid Readout Fluorescence System Product authorized by ANMAT PM 1614-1 Hole with special paper Plastic cap Plastic tube Identification label Process indicator Glass…

Terragene IC10 20FR Bionova Auto Reader Instruction Manual

९ डिसेंबर २०२३
Terragene IC10 20FR Bionova Auto Reader Specifications Product: Biological Indicators and Hygiene Monitoring System Material: Contains dry natural rubber Expiry Date: May 2025 Power Supply: 12 Volts DC Composition Product…

Terragene IC10 Auto Reader Incubator User Guide

१ नोव्हेंबर २०२१
Terragene IC10 Auto Reader Incubator Bionova® IC10/20FRLCD Auto-reader Symbols Humidity limitation Temperature limit Caution Caution, hot surface CE Mark Direct current For indoor use only Keep away from sunlight Batch…

जैविक निर्देशक आणि स्वच्छता देखरेख प्रणालींसाठी टेराजीन IU-IC1020-ड्युअल ड्युअल इनक्यूबेटर वापरकर्ता पुस्तिका

९ ऑक्टोबर २०२४
Terragene IU-IC1020-DUAL Dual Incubator For Biological Indicators and Hygiene Monitoring Systems  Product Information Model: IC10/20 Revision: 22/04/2022 Language: English, Italian, Japanese Function: Dual Incubator For Biological Indicators and Hygiene Monitoring…

MiniBio Auto-reader Incubator Product Overview

उत्पादन संपलेview
Technical specifications, usage guidelines, and regulatory information for the Terragene MiniBio Auto-reader Incubator, designed for rapid biological indicator readout.

Bionova® MiniBio Auto-reader User Manual

मॅन्युअल
Official user manual for the Bionova® MiniBio Auto-reader by Terragene, covering setup, operation, configuration, and maintenance for sterilization process control.

Bionova® Hyper Auto-reader: User Manual and Quick Start Guide

वापरकर्ता मॅन्युअल
Comprehensive guide for the Terragene Bionova® Hyper Auto-reader, detailing its features, setup, operation, safety precautions, technical specifications, and troubleshooting for monitoring sterilization processes using SCBI indicators.

Bionova® Photon Auto-reader: User Guide and Specifications | Terragene

जलद सुरुवात मार्गदर्शक / वापरकर्ता पुस्तिका
Comprehensive guide for the Terragene Bionova® Photon Auto-reader, detailing its features, usage instructions, safety information, technical specifications, and compliance for monitoring steam sterilization cycles.

Terragene support FAQ

या ब्रँडसाठी मॅन्युअल, नोंदणी आणि समर्थन याबद्दल सामान्य प्रश्न.

  • How do I store Terragene Bionova Biological Indicators?

    Store Bionova Biological Indicators in a dark place at an ambient temperature between 10-30 °C and 30-80% relative humidity. Never freeze them, and ensure they are not stored near sterilizing agents or other chemical products.

  • Why do I need a positive control when running a sterilization cycle check?

    Using a non-sterilized Self-Contained Biological Indicator (SCBI) from the exact same batch as a positive control ensures that the incubation conditions were met properly, the medium promotes rapid growth, and that the spore viability hasn't been compromised due to improper storage. A valid test requires the positive control to show positive fluorescence readout.

  • How do I use a Bionova Auto-reader Incubator?

    First, check your specific Terragene SCBI to ensure it matches the appropriate incubation time and temperature. Once an SCBI has been removed from a finished sterilization cycle and allowed to cool, press its lid to seal the tube, crush the internal ampoule using the provided ampoule crusher, and shake vigorously. Place the wetted SCBI into an empty position in the designated Bionova Auto-reader to begin automated fluorescence monitoring.

  • What does a color change to green or yellow mean on the indicators?

    For BT98 SCBIs, a process label color change from purple to green indicates exposure to hydrogen peroxide, though it does not guarantee sterilization. If after the incubation period the culture medium itself changes color (typically to yellow), it denotes a positive result (presence of living spores), indicating a sterilization process failure.