रेंजव्ह्यू सिरीज रडार वॉटर लेव्हल सेन्सर्स

"

तपशील:

  • Product Name: RangeVueTM15 and RangeVueTM30 Radar Water Level
    सेन्सर्स
  • तारीख: ०७/२०२४

उत्पादन माहिती:

The RangeVueTM15 and RangeVueTM30 Radar Water Level Sensors are
advanced sensors designed for accurately measuring water levels.
They come with a comprehensive manual that covers installation,
operation, maintenance, and diagnostics.

उत्पादन वापर सूचना:

1. परिचय

Read through the manual thoroughly to understand the features
and functions of the RangeVue sensors.

2. खबरदारी

Follow safety guidelines provided in the manual to ensure proper
installation and operation of the sensors.

१. प्रारंभिक तपासणी

When unpacking the equipment, ensure to do so in a clean, dry
area. Check for any shipping damage and contact the manufacturer if
आवश्यक

4. क्विकस्टार्ट

  1. Open Short Cut and create a new program.
  2. Select the data logger model and wire the sensor
    त्यानुसार
  3. Set up the scan rate, table name, and data output storage
    मध्यांतर
  4. Select output options and save the program.
  5. Check sensor output in LoggerNet, RTDAQ, or PC400 for
    पडताळणी

वारंवार विचारले जाणारे प्रश्न:

Q: What scan rate is recommended for measurements using
SDI-12?

अ: कampbell Scientific recommends measurement scans of 10
seconds or more due to delays using SDI-12.

"`

उत्पादन मॅन्युअल
RangeVueTM15 and RangeVueTM30
रडार वॉटर लेव्हल सेन्सर्स
07/2024
कॉपीराइट © 2024 Campबेल सायंटिफिक, इंक.

कृपया प्रथम वाचा
या मॅन्युअल बद्दल
कृपया लक्षात घ्या की या मॅन्युअलची निर्मिती सीampbell Scientific Inc. प्रामुख्याने उत्तर अमेरिकन बाजारपेठेसाठी. काही शब्दलेखन, वजने आणि मापे हे दर्शवू शकतात. याव्यतिरिक्त, मॅन्युअलमधील बहुतेक माहिती सर्व देशांसाठी बरोबर असली तरी, काही माहिती उत्तर अमेरिकन बाजारपेठेसाठी विशिष्ट आहे आणि त्यामुळे युरोपियन वापरकर्त्यांना लागू होऊ शकत नाही. फरकांमध्ये यूएस मानक बाह्य वीज पुरवठा तपशील समाविष्ट आहेत जेथे काही माहिती (उदाample एसी ट्रान्सफॉर्मर इनपुट व्हॉल्यूमtagई) ब्रिटिश/युरोपियन वापरासाठी लागू होणार नाही. तथापि, कृपया लक्षात ठेवा की जेव्हा वीज पुरवठा अडॅप्टर C वरून ऑर्डर केला जातोampबेल सायंटिफिक ते तुमच्या देशात वापरण्यासाठी योग्य असेल.
काही रेडिओ ट्रान्समीटर, डिजिटल सेल फोन आणि एरियल (अँटेना) संदर्भ देखील तुमच्या परिसरानुसार लागू होणार नाहीत. वायरिंगसह काही कंस, ढाल आणि संलग्न पर्याय युरोपियन बाजारपेठेत मानक वस्तू म्हणून विकले जात नाहीत; काही प्रकरणांमध्ये पर्याय दिले जातात.
WEEE नियम 2012/19/EU च्या अधीन असलेल्या देशांसाठी पुनर्वापराची माहिती
या उत्पादनाच्या आयुष्याच्या शेवटी ते व्यावसायिक किंवा घरगुती कचरा टाकू नये परंतु पुनर्वापरासाठी पाठवले जाऊ नये. उत्पादनामध्ये समाविष्ट असलेल्या किंवा उत्पादनांच्या आयुष्यादरम्यान वापरल्या जाणाऱ्या कोणत्याही बॅटरी उत्पादनातून काढून टाकल्या पाहिजेत आणि द वेस्ट इलेक्ट्रिकल अँड इलेक्ट्रॉनिक इक्विपमेंट (WEEE) रेग्युलेशन 2012/19/EU नुसार योग्य रिसायकलिंग सुविधेकडे पाठवल्या पाहिजेत. सीampबेल सायंटिफिक उपकरणांच्या पुनर्वापरावर सल्ला देऊ शकते आणि काही प्रकरणांमध्ये संकलन आणि त्याची योग्य विल्हेवाट लावण्याची व्यवस्था करू शकते, जरी काही वस्तू किंवा प्रदेशांसाठी शुल्क लागू होऊ शकते. पुढील समर्थनासाठी, कृपया सीampबेल सायंटिफिक किंवा तुमचा स्थानिक एजंट.

सामग्री सारणी

1. परिचय

1

2. खबरदारी

1

3. प्रारंभिक तपासणी

2

4. क्विकस्टार्ट

2

5. ओवरview

5

6. तपशील

6

7. स्थापना

9

7.1 Wiring to the data logger

9

7.2 Data logger programming

10

7.2.1 CRBasic प्रोग्रामिंग

10

7.2.2 फील्ड स्थापना

11

7.2.3 Determine and set reference stage

15

8. ऑपरेशन

16

8.1 डीफॉल्ट सेटिंग्ज

16

8.2 SDI-12 commands

17

8.3 Configuring sensor via extended SDI-12 commands and terminal emulator

20

9. Maintenance, diagnostics, and repair

22

9.1 Testing procedure

23

9.2 चक्रीय रिडंडंसी चेक

23

परिशिष्ट A. CRBasic Editor मध्ये शॉर्ट कट कोड आयात करणे

24

Appendix B. SDI-12 version 1.4 identify measurement commands and

प्रतिसाद

25

Appendix C. FCC/IC equipment authorization (USA/Canada only)

27

सामग्री सारणी – i

1. परिचय
The RangeVueTM15 and RangeVueTM30 radar sensors monitor the water level of rivers, lakes, tidal seas, and reservoirs, and is ideal for areas where submersed sensors can be damaged due to corrosion, contamination, flood-related debris, lightning, or vandalism. The RangeVue 30 can measure distances up to 30 m (98.4 ft) and the RangeVue 15 can measure distances up to 15 m (49.2 ft). The RangeVue 15 and RangeVue 30 radar sensors output a digital SDI-12 signal to indicate distance and stage. The output is acceptable for recording devices with SDI-12 capability.
2. खबरदारी
l READ AND UNDERSTAND the Safety section at the back of this manual. l Follow country-specific installation standards, prevailing safety regulations, accident
prevention rules, and this manual’s safety instructions. The sensor is designed for safe operation in accordance with the current technical, safety, and ANSI standards. l The emitting frequencies of the RangeVue-series is well below the internationally permitted limits. When used correctly, the radar sensor presents no danger to people. l Do not attempt to install the sensor unless you are qualified to perform the installation. l Handle the sensor carefully, since it is a precision instrument. l If installing the sensor from tall structures over water, use appropriate safety equipment such as a safety harness or a life preserver when installing or performing maintenance on the sensor. l The user is responsible for ensuring that the sensor is maintained and functioning properly.
RangeVue-Series Radar Water-Level Sensors 1

3. प्रारंभिक तपासणी
When unpacking the equipment, do the following: l Unpack the unit in a clean, dry area. l Carefully open the shipping package, ensuring that the cable jacket is not damaged or cut. Contact Campbell Scientific if the cable was damaged during unpacking. l Inspect the equipment for any damage that occurred during shipping. If equipment was damaged during shipping, file a claim with the carrier and report the damage in detail.
4. क्विकस्टार्ट
शॉर्ट कट वापरून डेटा लॉगर प्रोग्रामिंगचे वर्णन करणारा व्हिडिओ येथे उपलब्ध आहे: www.campbellsci.com/videos/cr1000x-data logger-getting-started-program-part-3 . सेन्सर मोजण्यासाठी आणि डेटा लॉगर वायरिंग टर्मिनल नियुक्त करण्यासाठी तुमचा डेटा लॉगर प्रोग्राम करण्याचा शॉर्ट कट हा एक सोपा मार्ग आहे. शॉर्ट कट www.c वर डाउनलोड म्हणून उपलब्ध आहेampbellsci.com . It is included in installations of LoggerNet, RTDAQ, and PC400. The following procedure also shows using Short Cut to program the RangeVue-series.
1. शॉर्ट कट उघडा आणि नवीन प्रोग्राम तयार करा क्लिक करा. 2. डेटा लॉगर मॉडेलवर डबल-क्लिक करा.
RangeVue-Series Radar Water-Level Sensors 2

3. In the Available Sensors and Devices box, type RangeVue or find the sensor in the Sensors > Water > Level & Flow folder, and double-click RangeVue15/RangeVue30 Radar Water Level Sensor. SDI-12 Address defaults to 0. Enter the correct SDI-12 Address if the address has been changed from the factory default value. Check the Measure concurrently box if you want to use the C! SDI-12 command. By default, the sensor units are meters and degrees Celsius. The units are changed using the extended SDI-12 commands (Configuring sensor via extended SDI-12 commands and terminal emulator [p. 20]).
4. Click the Wiring tab. Click OK after wiring the sensor.
5. Repeat steps three and four for other sensors you want to measure. Click Next.
RangeVue-Series Radar Water-Level Sensors 3

6. In Output Setup, type the scan rate, a Table Name, and Data Output Storage Interval. Click Next.
NOTE: Because of the delays using SDI-12, Campbell Scientific recommends measurement scans of 10 seconds or more. 7. Select the output options.
8. Finish वर क्लिक करा आणि प्रोग्राम सेव्ह करा. डेटा लॉगर संगणकाशी जोडलेला असल्यास प्रोग्राम डेटा लॉगरला पाठवा.
9. सेन्सर डेटा लॉगरशी कनेक्ट केलेला असल्यास, लॉगरनेट, RTDAQ किंवा PC400 मधील डेटा डिस्प्लेमध्ये सेन्सरचे आउटपुट वाजवी मोजमाप करत असल्याची खात्री करण्यासाठी तपासा.
RangeVue-Series Radar Water-Level Sensors 4

5. ओवरview
The radar sensor consists of an integrated microwave transmitter and sensor. A built-in SDI-12 interface provides data processing and SDI-12 communications with the data logger. The RangeVue-series emits a continuous, frequency-modulated radar signal and measures the elapsed time between the emission and return of the signal. The elapsed time measurement is used to calculate the distance between the sensor face and the target (for example, water, grain, slurry). The distance value is used to determine depth of the medium (Figure 5-1 [p. 5]).
Figure 5-1. RangeVue-series stage, distance, and offset The RangeVue 30 can measure distances up to 30 m (98.4 ft) and the RangeVue 15 can measure distances up to 15 m (49.2 ft). The RangeVue 15 also has mounting threads to facilitate pipe mounting.
RangeVue-Series Radar Water-Level Sensors 5

वैशिष्ट्ये:
l Meets USGS Office of Surface Water (OSW) requirements for accuracy l SDI-12 1.4 functionality including SHEF coded metadata l Low power mode available l FCC compliant; individual FCC license not required l Low maintenance–no moving parts significantly reduces maintenance cost and time l Rugged enough for harsh environments–IP68 rating l Compatible with a Campbell Scientific Aspen 10 Edge Device l Compatible with any SDI-12 data logger/controller including Campbell Scientific GRANITE-
series, CR6, CR1000X, CR300-series, CR3000, CR800-series, and CR1000

6. तपशील

Measurement range RangeVue 30: RangeVue 15:

(d in Figure 6-1 [p. 6]) up to 30 m (98.43 ft) up to 15 m (49.21 ft)

Figure 6-1. Reference line for measurement range

Accuracy: Resolution: Output protocol: Frequency:

2 mm (±0.0065 ft) 1 mm (0.0033 ft) SDI-12 1.4 80 GHz

RangeVue-Series Radar Water-Level Sensors 6

Measuring cycle time:

250 ms

Step response time:

3s

बीम कोन

RangeVue 30:

७२°

RangeVue 15:

७२°

Emitted HF power (depends on the parameter setting)

Average spectral transmission power density:

­3 dBm/MHz EIRP

Maximum spectral transmission

power density:

+३४ डीबीएम/५० मेगाहर्ट्झ ईआयआरपी

Maximum power density at a distance of 1 m:

< 3 W/cm²

इनपुट व्हॉल्यूमtage:

8 ते 32 VDC

वीज वापर

कमाल:

200 मेगावॅट

Default-power mode:

100 mW at <18 VDC

लो-पॉवर मोड:

25 mW at <18 VDC; low power mode is set by the aXWPOM+p! SDI-12 command (Table 8-2 [p. 17])

तापमान श्रेणी

कार्यरत:

­40 to 80 °C

स्टोरेज:

­40 to 80 °C

कंपन प्रतिकार:

Mechanical vibrations with 5 g and 4 to 100 Hz

यांत्रिक रेटिंग:

IP66/68

गृहनिर्माण साहित्य:

PVDF plastic

Antenna material:

PVDF plastic

वजन:

0.7 किलो (1.5 पौंड)

परिमाणे:

See Figure 6-2 (p. 8) and Figure 6-3 (p. 8)

RangeVue-Series Radar Water-Level Sensors 7

Figure 6-2. RangeVue 15 dimensions
Figure 6-3. RangeVue 30 dimensions Compliance information: View येथे:
www.campbellsci.com/rangevue15 www.campbellsci.com/rangevue30
RangeVue-Series Radar Water-Level Sensors 8

7. स्थापना

If you are programming your data logger with Short Cut or are using the Aspen 10 Edge Device, skip Wiring to the data logger (p. 9) and Data logger programming (p. 10). See QuickStart (p. 2) for a Short Cut tutorial. For information about using the Aspen 10 with the RangeVue-series, refer to the Aspen 10 manual, available at www.campbellsci.com/aspen10 .
या विभागात खालील गोष्टींचा समावेश आहे:

7.1 Wiring to the data logger

9

7.2 Data logger programming

10

7.2.1 CRBasic प्रोग्रामिंग

10

7.2.2 फील्ड स्थापना

11

7.2.3 Determine and set reference stage

15

7.1 Wiring to the data logger
CAUTION: To avoid shock or damage to the instrument, never apply power while wiring.

CAUTION: Ensure that the RangeVue-series is properly wired to the data logger before applying power. Applying power when incorrectly wired could damage the RangeVue-series beyond repair.

Connect the RangeVue-series to the data logger in the order shown in Table 7-1 (p. 9).

तक्ता 7-1: वायर रंग, कार्य आणि डेटा लॉगर कनेक्शन

वायर रंग पांढरा

वायर फंक्शन SDI-12 सिग्नल

Data logger connection C1 or U configured for SDI-121

साफ

ढाल

G

तपकिरी

शक्ती

12V

काळा

उर्जा मैदान

G

1 C आणि U टर्मिनल मापन निर्देशांद्वारे स्वयंचलितपणे कॉन्फिगर केले जातात.

RangeVue-Series Radar Water-Level Sensors 9

If multiple SDI-12 sensors are connected to a data logger, Campbell Scientific recommends using separate terminals when possible. However, multiple SDI-12 sensors or multiple RangeVue-series sensors can connect to the same data logger control or U terminal. Each must have a unique SDI-12 address. Valid addresses are 0 through 9, a through z, and A through Z. The RangeVueseries ships with a default SDI-12 address of 0. For the CR6 and CR1000X, triggering conflicts may occur when a companion terminal is used for a triggering instruction such as TimerInput(), PulseCount(), or WaitDigTrig(). For example, if the RangeVue-series is connected to C3 on a CR1000X, C4 cannot be used in the TimerInput(), PulseCount(), or WaitDigTrig() instructions.
NOTE: After connecting the sensor to power, the sensor performs a BIST (built-in self-test) for approximately 50 seconds (factory default). During this self-check, an internal check of the electronics occurs.
7.2 Data logger programming
C साठी अद्ययावत प्रोग्रामिंग कोडसाठी शॉर्ट कट हा सर्वोत्तम स्त्रोत आहेampbell Scientific data loggers. If your data acquisition requirements are simple, you can probably create and maintain a data logger program exclusively with Short Cut. If your data acquisition needs are more complex, the files that Short Cut creates are a great source for programming code to start a new program or add to an existing custom program.
NOTE: Short Cut cannot edit programs after they are imported and edited in CRBasic Editor.
A Short Cut tutorial is available in QuickStart (p. 2). If you wish to import Short Cut code into CRBasic Editor to create or add to a customized program, follow the procedure in Importing Short Cut code into CRBasic Editor (p. 24). Programming basics for CRBasic data loggers are provided in the following sections. Downloadable example programs are available at www.campbellsci.com/downloads/rangevue-example-programs .
7.2.1 CRBasic प्रोग्रामिंग
This instruction sends a request to the sensor to make a measurement and then retrieves the measurement from the sensor. See for more information. For most data loggers, the SDI12Recorder() instruction has the following syntax:
SDI12Recorder(गंतव्य, SDIPort, SDIAddress, “SDICommand”, गुणक, ऑफसेट, FillNAN, WaitonTimeout)
RangeVue-Series Radar Water-Level Sensors 10

SDIA पत्त्यासाठी, वर्णमाला अक्षरे अवतरण चिन्हांमध्ये संलग्न करणे आवश्यक आहे (उदा.ample, “A”). Also enclose the SDICommand in quotation marks as shown. The Destination parameter must be an array. The required number of values in the array depends on the command (see ). FillNAN and WaitonTimeout are optional parameters (refer to the CRBasic Editor help for more information).
7.2.2 फील्ड स्थापना
Consider the following while selecting the site:
l Sensor height: Mount the sensor high enough to prevent submersion during flooding conditions.
WARNING: Since the sensor is commonly installed over water from tall structures, use appropriate safety equipment such as a safety harness or a life preserver when installing or performing maintenance on the sensor.
l Water surface: Install the sensor above the smoothest part of the water surface.
NOTE: The smoothest part of the water surface is typically found halfway between bridge piers. However, bridges with long spans between the piers experience more vibration. For these bridges, vibration can be minimized by mounting the sensor a quarter to a third of the distance to the next pier.
l Horizontal structures: Avoid mounting near horizontal structural surfaces such as beams, brackets, and sidewall joints because these surfaces reflect a strong signal.
l Obstructions: Mount the sensor away from obstructions (both above and under water) in the radiation beam path, which spreads as it leaves the sensor. Obstructions to be aware of include excessive waves, splashing, pipes, wires, rocks, bridge piers, and logs. Determine the required clearance for the beam angle using the following formulas and Figure 7-1 (p. 12). Clearance diameter formulas: RV30CONEdiameter = 0.070(CONEdistance) RV15CONEdiameter = 0.141(CONEdistance) Where, CONEdistance = the distance to the reference line (Figure 6-1 [p. 6])
RangeVue-Series Radar Water-Level Sensors 11

RV30CONEdiameter = clearance diameter for the RangeVue 30 in the same measurement units as the CONEdistance RV15CONEdiameter = clearance diameter for the RangeVue 15 in the same measurement units as the CONEdistance
Figure 7-1. Beam path clearances CAUTION: Be aware that bridges contract and expand with temperature changes. Traffic loads or trucks can also cause changes to the bridge height.
After choosing an appropriate site, mount and align the sensor using the following procedure: 1. Secure the RangeVue-series bracket to a 1-inch diameter nominal pipe) using the V-clamp, washers, lock washers, and nuts (see Figure 7-2 [p. 13]).
RangeVue-Series Radar Water-Level Sensors 12

Figure 7-2. RangeVue 15 mounted in the RangeVue-series bracket 2. Place the RangeVue-series in the bracket (see Figure 7-2 [p. 13] and Figure 7-3 [p. 13]).
Figure 7-3. RangeVue-series bracket 3. Orient the sensor such that the middle of the sensor label is aligned or parallel with the wall
or pier (Figure 7-4 [p. 14] and Figure 7-5 [p. 14]).
RangeVue-Series Radar Water-Level Sensors 13

Figure 7-4. Polarization markings
Figure 7-5. RangeVue 15 mounted near wall (cable not connected). RangeVue-Series Radar Water-Level Sensors 14

4. Use a bubble level to make certain the antenna horn is aligned within 1° of vertical. A measurement error will be introduced if the antenna is not perpendicular to the water surface. The maximum range is reduced because of the off-axis return signal.
5. Secure the RangeVue-series to the bracket by tightening the counter nut (see Figure 7-2 [p. 13] and Figure 7-6 [p. 15]).
Figure 7-6. Counter nut on the RangeVue 30. 6. Connect the cable, route it to the data logger, then secure it to the bracket and mounting
pipe using cable ties.
7.2.3 Determine and set reference stage
Change the reference stage setting at deployment. This setting allows the sensor to complete an offset calculation. Every future measurement will use the offset and the current distance measurement to calculate water stage or depth. Using a staff plate or other physical datum, measure water level at the measurement site. Record the measurement. Ensure that the measurement is in the same units as the sensor unit setting. Default value is feet. Enter reference stage using a terminal emulator (Configuring sensor via extended SDI-12 commands and terminal emulator [p. 20]).
RangeVue-Series Radar Water-Level Sensors 15

8. ऑपरेशन

This section discusses the following.

8.1 डीफॉल्ट सेटिंग्ज

16

8.2 SDI-12 commands

17

8.3 Configuring sensor via extended SDI-12 commands and terminal

emulator

20

8.1 डीफॉल्ट सेटिंग्ज

Table 8-1 (p. 16) shows the default settings. The default settings are changed using SDI-12 commands (Table 8-2 [p. 17]) and a terminal emulator (Configuring sensor via extended SDI-12 commands and terminal emulator [p. 20]). The reference stage settings must be changed. The other default settings can be used in most circumstances.

Table 8-1: Default settings

Setting SDI-12 address

डीफॉल्ट
0 (change only if two sensors are connected to the same terminal) valid addresses are 0 through 9, A through Z, and a
through z.

Read or write Read/write

Power mode Stage/distance units

1 = normal 0 = meter

Read/write Read/write

Temperature units Stage संदर्भ

degree Celsius 0

वाचा/लिहा
Must be set using a terminal emulator. Refer to Configuring
sensor via extended SDI-12 commands and terminal emulator (p. 20)

RangeVue-Series Radar Water-Level Sensors 16

8.2 SDI-12 commands
Table 8-2 (p. 17) shows the measurement and extended SDI-12 commands for the RangeVueseries. The RangeVue-series responds to the M!, C!, CC!, R0!, and R0C! SDI-12 measurement commands. When using an M! command, the data logger waits for the time specified by the sensor, sends the D! command, pauses its operation, and waits until either it receives the data from the sensor or the sensor timeout expires. If the data logger receives no response, it will send the command a total of three times, with three retries for each attempt, or until a response is received.
The C! command follows the same pattern as the M! command with the exception that it does not require the data logger to pause its operation until the values are ready. Rather, the data logger retrieves the data with the D! command on the next pass through the program. Another measurement request is then sent so that data are ready on the next scan.
The R0! command directly reads the sensor measurements and outputs all of its values.
The MC!, CC!, and R0C! commands are the same as the previous commands, but where the C at the end of the command forces a validation for the data received from the sensor using a checksum. If the checksum is invalid, the data logger will re-request the data up to three times. The checksum validation increases the measurement time by about 40 milliseconds if there are no errors. Retries will increase the measurement time in proportion to the number of retries. The checksum option is necessary only for long cable lengths or when electronic noise may impact measurement transmission to the data logger.
Information about using the extended commands are provided in Configuring sensor via extended SDI-12 commands and terminal emulator (p. 20).
NOTE: Additional SDI-12 information is available at www.sdi-12.org .

Table 8-2: SDI-12 measurement and extended commands

SDI-12 कमांड1

परत आलेली मूल्ये किंवा कार्य

aM!, aC!, aCC!, aR0!,aRC0!

1. एसtage 2. Distance 3. Electronics temperature 4. Signal-to-noise (SNR) ratio2

५.१. डिव्हाइस स्थिती

aXRPOM!

Read power operation mode

RangeVue-Series Radar Water-Level Sensors 17

Table 8-2: SDI-12 measurement and extended commands

SDI-12 कमांड1

परत आलेली मूल्ये किंवा कार्य

aXWPOM+p!

Write power operation mode. It returns:

कुठे,

aXWPOM+p+nnn!

p =power operation mode code Where,

p is the power operation mode code:

0=low power mode 1=normal power mode
nnn is the status code3

aXRDU!

Read distance units

कुठे:

aXWDU+d! Where,

0=m 1=ft 2=mm 3=inch
Write distance unit code. It returns:
aXWDU+d+nnn!

d =distance unit code

कुठे,

d is the distance unit code

0=m 1=ft 2=mm 3=inch
nnn is the status code3

aXRTU!

Read temperature units

कुठे:

0=°C 1=°F 2=K

RangeVue-Series Radar Water-Level Sensors 18

Table 8-2: SDI-12 measurement and extended commands

SDI-12 कमांड1

परत आलेली मूल्ये किंवा कार्य

aXWTU+t! Where,

Write temperature units. It returns: aXWTU+t+nnn!

t =temperature unit code

कुठे,

t is the temperature unit code

0=°C 1=°F 2=K
nnn = status code3

aXRS! aXSS+ssssssss! Where,

एस वाचाtage reference Set stage reference. It returns:
aXSS+ssssssss+nnn!

ssssssss =stage संदर्भ

कुठे,

ssssssss is the stage reference. The format depends on units:

ssss.sss for meter sssss.ss for feet sssssss for millimeter sssssss for inch
nnn is the status code3

aV!

1. Operating system (OS) version

५.१. डिव्हाइस स्थिती

?!

SDI-12 पत्ता

1a is the sensor address. In the SDI12Recorder() CRBasic instruction, the command parameter does not include the SDI-12 address because the address is a separate parameter.
2A higher signal-to-noise ratio (SNR) signifies a stronger and clearer radar signal relative to the noise. A good SNR can vary based on several factors including the specific sensor design, operating environment, and application requirements. As a general guideline, above 10 dB is the minimum threshold to reliably distinguish the signal from noise and interference. A SNR above 20 dB is a very good SNR, indicating a strong and clear signal with minimal interference, which can lead to highly accurate measurements.
3The status code is 000 if valid data is sent and 136 if invalid data is sent.

RangeVue-Series Radar Water-Level Sensors 19

8.3 Configuring sensor via extended SDI-12 commands and terminal emulator
The RangeVue-series is fully configurable using SDI-12 extended commands through a terminal emulator program. The following instructions step you through the initial setup process. Table 82 (p. 17) lists all the extended SDI-12 commands and the values that are returned. It is possible to completely reset the sensor to factory defaults settings as well. Most of the extended SDI-12 commands require 2 seconds to complete the change when the sensor is in normal power mode.
1. Connect the RangeVue-series to your data logger (Wiring to the data logger [p. 9]). 2. Connect to the data logger using LoggerNet and open the terminal emulator. In LoggerNet,
the terminal emulator is located at: LoggerNet > Main > Connect > data logger > Terminal Emulator. 3. Click Open Terminal. 4. Press Enter until a prompt appears.
३. जर C वापरत असाल तरampbell Scientific data logger, type SDI12 <Enter> once the prompt is present.
RangeVue-Series Radar Water-Level Sensors 20

6. Enter the number corresponding to the terminal your sensor is wired into.
7. Set the Current or Reference Stage. This should be set at deployment. Using a staff plate or other physical datum at the study site, measure and enter the current stage. This allows the sensor to complete an offset calculation based on the entered stage and the measured distance to water surface. Every future measurement will use the offset and measured distance to water surface to calculate water stage or depth. Command: 0XSS+50! (where 50 is the reference stage) Response: 0+50.000+000 The sensor response includes the sensor address (0) + reference stage (50.000) + status code (000).
RangeVue-Series Radar Water-Level Sensors 21

8. The default SDI-12 address for the sensor is 0. Change the sensor address if you will have more than one SDI-12 sensor on the same terminal with the aAb! command, where a is the current sensor address and b is the desired address. The sensor will respond with the new address if it was successfully changed.
Command: 0A1! Response: 1 9. The default stage/distance units are meters. To change the units, use the aXWDU+d! command, where d is 0 (meters), 1 [feet], 2 (millimeters), or 3 (inches). Refer to SDI-12 commands (p. 17) for more information. 10. The default temperature units are degree Celsius. To change the units, use the aXWTU+t!, where t is 0 (°C), 1 (°F), or 2 (K). Refer to SDI-12 commands (p. 17) for more information. 11. Set the Power Mode of the sensor. The default power mode is normal and has a numeric code of 1. Low power mode turns off the processor of the sensor in between measurements consuming significantly less power. However, it will take longer to respond to each measurement command since it will power down after a measurement is complete. Measurement time will be a function of boot time and the integration time. To run in low power mode, use the following command.
Command: 0XWPOM+0! Response: 0+0+000
The sensor response includes the sensor address (0) + power mode (0) + error code (000).
9. Maintenance, diagnostics, and repair
NOTE: All factory repairs and recalibrations require a returned material authorization (RMA) and completion of the “Statement of Product Cleanliness and Decontamination” form. Refer to the Assistance page at the end of this manual for more information.
The RangeVue-series is maintenance free under normal operation.
RangeVue-Series Radar Water-Level Sensors 22

9.1 Testing procedure
1. Double-check all wiring connections. CAUTION: The data logger cannot issue SDI-12 commands when a USB cable is connected to the sensor.
2. Connect the sensor to your data logger and apply +12 V power. 3. Send the Acknowledge Active command (a!). This command is used to check the presence
of the sensor on the bus. Only the address is sent back in response. 4. Send the Identification command (aI!). 5. Compare the output stage versus the actual stage using the Start Measurement command
(aM!) followed by the Send Data command (aD!).
9.2 चक्रीय रिडंडंसी चेक
The cyclic redundancy check (CRC) is used to produce and send a small, fixed-size checksum of a larger block of data to the data logger. This checksum detects errors after transmission or storage. The CRC is computed and added before any transmission or storage. The CRC is also authenticated by the recipient, after the transmission, to confirm that no alterations occurred. CRCs are good at identifying errors caused by noise in transmission channels.
RangeVue-Series Radar Water-Level Sensors 23

परिशिष्ट A. CRBasic Editor मध्ये शॉर्ट कट कोड आयात करणे
शॉर्ट कट .DEF तयार करतो file ज्यामध्ये वायरिंग माहिती आणि एक प्रोग्राम आहे file जे CRBasic Editor मध्ये आयात केले जाऊ शकते. डीफॉल्टनुसार, हे files C:c मध्ये राहतातampbellsciSCWin फोल्डर. शॉर्ट कट प्रोग्राम आयात करा file आणि CRBasic Editor मध्ये वायरिंग माहिती:
1. शॉर्ट कट प्रोग्राम तयार करा, नंतर सेव्ह करा. प्रगत टॅब नंतर CRBasic Editor बटणावर क्लिक करा. आपला कार्यक्रम file जेनेरिक नावाने CRBasic मध्ये उघडेल. अर्थपूर्ण नाव द्या आणि CRBasic प्रोग्राम सेव्ह करा. हा प्रोग्राम आता अतिरिक्त शुद्धीकरणासाठी संपादित केला जाऊ शकतो. टीप: एकदा file CRBasic Editor सह संपादित केले आहे, शॉर्ट कट यापुढे प्रोग्राम संपादित करण्यासाठी वापरला जाऊ शकत नाही.
2. नवीन CRBasic प्रोग्राममध्ये शॉर्ट कट वायरिंग माहिती जोडण्यासाठी, .DEF उघडा. file C:c मध्ये स्थित आहेampbellsciSCWin फोल्डर. .DEF च्या सुरवातीला सापडलेली वायरिंग माहिती कॉपी करा file.
3. CRBasic प्रोग्राममध्ये जा आणि प्रोग्रामच्या सुरुवातीला वायरिंगची माहिती पेस्ट करा.
4. CRBasic प्रोग्राममध्ये, वायरिंग माहिती हायलाइट करा, उजवे-क्लिक करा आणि Comment Block निवडा. हे हायलाइट केलेल्या प्रत्येक ओळीच्या सुरुवातीला एक अपॉस्ट्रॉफी (') जोडते, जे डेटा लॉगर कंपाइलरला संकलित करताना त्या ओळींकडे दुर्लक्ष करण्याची सूचना देते. कॉमेंट ब्लॉक वैशिष्ट्य CRBasic | मध्ये सुमारे 5:10 वाजता प्रदर्शित केले जाते व्हिडिओची वैशिष्ट्ये.
RangeVue-Series Radar Water-Level Sensors 24

Appendix B. SDI-12 version 1.4 identify measurement commands and responses

Version 1.4 compliant sensors must respond to identify commands for each type of measurement command and each parameter with a command. The broad identify commands return how many variables will be returned with a given measurement command and the time it will take the sensor to respond. The specific identify parameter commands will return a SHEF code, the measurement units, and the type of measurement (sample, count, or average). For more information see the SDI-12 version 1.4 specification.

(http://sdi-12.org/current_specification/SDI-12_version-1_4-Jan-10-2019.pdf )

Table B-1: Identify commands for the RangeVue-series

Type of command

Command Sensor response

टिप्पणी द्या

Identify Measurement for `M’ Commands

aIM!, aIMC!

atttn

ttt: response time n: # of values returned

Identify Measurement for `C’ Commands

aIC!, aICC!

atttnn

ttt: response time nn: # of values returned

Identify Measurement for the `V’ Command

aIV!

atttn

ttt: response time n: # of values returned

RangeVue-Series Radar Water-Level Sensors 25

Table B-2: Identify measurement parameters for M! and C! commands

पॅरामीटर
Stage अंतर

आज्ञा

M! aIM_001!

C! aIC_001!

aIM_002!

aIC_002!

सेन्सर प्रतिसाद
a,hg,m; a,ha,m;

इलेक्ट्रॉनिक्स तापमान

aIM_003!

aIC_003!

a,TempElectronic,degrees C;

Level reliability
डिव्हाइस स्थिती

aIM_004! aIM_005!

aIC_004! aIC_005!

a,LevelReliability,dB; a,DeviceStatus;

RangeVue-Series Radar Water-Level Sensors 26

Appendix C. FCC/IC equipment authorization (USA/Canada only)
The RangeVue-series is FCC compliant (FCC IC # M01PULS616263). Modifications to the sensor must have express agreement from Campbell Scientific. Any modifications not approved by Campbell Scientific will cause the expiration of the operating license issued by the FCC/IC. The radar sensor is in conformity with Part 15 of the FCC directives and fulfills the RSS-210 regulations. Regulations for operation include:
l These devices must not cause any interfering emissions. l These devices must accept any interfering emissions received, including interference that
may cause unwanted operating conditions.
RangeVue-Series Radar Water-Level Sensors 27

मर्यादित वॉरंटी
कव्हर केलेले उपकरणे तुमच्या विक्री बीजक किंवा उत्पादन ऑर्डर माहितीवर सूचीबद्ध केलेल्या कालावधीसाठी सामान्य वापर आणि सेवा अंतर्गत सामग्री आणि कारागिरीतील दोषांविरुद्ध हमी/ हमी दिली जाते web पृष्ठ कव्हर केलेला कालावधी शिपमेंटच्या तारखेपासून सुरू होतो जोपर्यंत अन्यथा निर्दिष्ट केला जात नाही. वॉरंटी अंतर्गत दुरुस्तीसाठी, खालील निकषांची पूर्तता करणे आवश्यक आहे:
1. साहित्य किंवा कारागिरीमध्ये दोष असणे आवश्यक आहे जे डिव्हाइसचे स्वरूप, फिट किंवा कार्य प्रभावित करते.
2. दोष हा गैरवापराचा परिणाम असू शकत नाही.
3. दोष निर्दिष्ट कालावधीत आला असावा; आणि
4. सी मधील पात्र तंत्रज्ञाने निर्धार केला पाहिजेampघंटा वैज्ञानिक सेवा केंद्र / दुरुस्ती सुविधा.
खालील कव्हर केलेले नाही:
1. सी च्या लेखी परवानगीशिवाय कोणत्याही प्रकारे बदल किंवा बदल केलेली उपकरणेampघंटा वैज्ञानिक.
2. बॅटरी; आणि
3. कोणतीही उपकरणे ज्याचा गैरवापर, दुर्लक्ष, देवाची कृत्ये किंवा संक्रमणामध्ये नुकसान झाले आहे.
Campbell Scientific प्रादेशिक कार्यालये त्यांच्या प्रदेशातील ग्राहकांसाठी दुरुस्ती हाताळतात. प्रादेशिक कार्यालयांच्या यादीसाठी कृपया मॅन्युअलचे मागील पृष्ठ पहा किंवा www.c ला भेट द्याampbellsci.com/contact कोणते सीampबेल सायंटिफिक ऑफिस तुमच्या देशाची सेवा करते. उपकरणे कशी परत करायची याच्या दिशानिर्देशांसाठी, सहाय्य पहा.
इतर निर्मात्याची उत्पादने, जी C द्वारे पुन्हा विकली जातातampबेल सायंटिफिक, केवळ मूळ निर्मात्याने वाढवलेल्या मर्यादेपर्यंत हमी दिली जाते.
CAMPबेल वैज्ञानिक स्पष्टपणे अस्वीकरण करते आणि कोणतीही गर्भित हमी वगळते
विशिष्ट हेतूसाठी व्यापारीता किंवा योग्यता. सीampबेल सायंटिफिक याद्वारे, लागू कायद्याद्वारे परवानगी असलेल्या पूर्ण मर्यादेपर्यंत, उत्पादनांच्या संदर्भात कोणतीही आणि सर्व वॉरंटी आणि शर्ती, स्पष्टपणे प्रदान केलेल्या व्यतिरिक्त, स्पष्ट, निहित किंवा वैधानिक, अस्वीकरण करते.
Campबेल सायंटिफिक, डीफॉल्ट म्हणून, पृष्ठभाग वाहक प्रीपेडद्वारे वॉरंटेड उपकरणे परत करेल. तथापि, रिटर्न शिपमेंटची पद्धत सी येथे आहेampbell Scientific च्या विवेकबुद्धीनुसार. सीampबेल सायंटिफिक उपकरणे काढून टाकण्यासाठी आणि/किंवा पुन्हा स्थापित करण्याच्या खर्चासाठी दावेदाराला परतफेड करणार नाही. ही वॉरंटी आणि त्याखालील कंपनीचे दायित्व इतर सर्वांच्या बदल्यात आहे

वॉरंटी, व्यक्त किंवा निहित, विशिष्ट हेतूसाठी उपयुक्तता आणि फिटनेससह. सीampबेल सायंटिफिक परिणामी नुकसानीसाठी जबाबदार नाही.
या वॉरंटीच्या तरतुदी आणि C च्या तरतुदींमध्ये कोणताही संघर्ष किंवा विसंगती आढळल्यासampbell Scientific च्या अटी, C च्या तरतुदीampbell Scientific च्या अटी प्रचलित राहतील. शिवाय, सीampबेल सायंटिफिकच्या अटी या वॉरंटीमध्ये संदर्भाद्वारे समाविष्ट केल्या आहेत. ला view C ला लागू होणाऱ्या अटी व शर्तीampbell Scientific, Logan, UT, USA, अटी आणि नियम पहा. ला view C ला लागू होणाऱ्या अटी आणि शर्तीampयुनायटेड स्टेट्सबाहेरील वैज्ञानिक कार्यालयांची घंटी वाजवा, तुमच्या देशाला सेवा देणाऱ्या प्रादेशिक कार्यालयाशी संपर्क साधा.

सहाय्य
पूर्व परवानगीशिवाय उत्पादने परत केली जाऊ शकत नाहीत. कृपया उपकरणे परत करण्यापूर्वी आम्हाला कळवा आणि रिटर्न मटेरियल ऑथोरायझेशन (RMA) क्रमांक मिळवा की दुरुस्ती वॉरंटी/गॅरंटी अंतर्गत आहे की नाही. कव्हर केलेल्या उपकरणांच्या माहितीसाठी मर्यादित वॉरंटी पहा.
Campbell Scientific प्रादेशिक कार्यालये त्यांच्या प्रदेशातील ग्राहकांसाठी दुरुस्ती हाताळतात. प्रादेशिक कार्यालयांच्या यादीसाठी कृपया मॅन्युअलचे मागील पृष्ठ पहा किंवा www.c ला भेट द्याampbellsci.com/contact कोणते सीampबेल सायंटिफिक ऑफिस तुमच्या देशाची सेवा करते.
उपकरणे परत करताना, पॅकेजच्या बाहेर RMA क्रमांक स्पष्टपणे चिन्हांकित करणे आवश्यक आहे. कृपया दोष शक्य तितक्या स्पष्टपणे सांगा. विनंतीनुसार दुरुस्तीसाठी कोटेशन दिले जाऊ शकतात.
सी चे धोरण आहेampबेल सायंटिफिक आपल्या कर्मचाऱ्यांच्या आरोग्याचे रक्षण करण्यासाठी आणि सुरक्षित कार्य वातावरण प्रदान करण्यासाठी. या धोरणाच्या समर्थनार्थ, जेव्हा उपकरणे C ला परत केली जातातampbell Scientific, Logan, UT, USA, रिटर्नची प्रक्रिया होण्यापूर्वी “धोकादायक सामग्री आणि निर्जंतुकीकरणाची घोषणा” फॉर्म प्राप्त करणे अनिवार्य आहे. उत्पादन मिळाल्यानंतर 5 कामकाजाच्या दिवसांत फॉर्म प्राप्त झाला नाही किंवा तो अपूर्ण असल्यास, ग्राहकाच्या खर्चावर उत्पादन ग्राहकाला परत केले जाईल. तुमच्या देशाशी संबंधित निर्जंतुकीकरण मानकांच्या तपशीलांसाठी, कृपया तुमच्या प्रादेशिक C शी संपर्क साधाampघंटा वैज्ञानिक कार्यालय.
टीप: व्यापाराच्या सीमा ओलांडणाऱ्या सर्व वस्तू काही प्रकारच्या शुल्काच्या अधीन असू शकतात (सीमाशुल्क मंजुरी, शुल्क किंवा आयात कर). तसेच, जर एखादे उत्पादन वॉरंटी कालावधी संपले असेल तर काही प्रादेशिक कार्यालयांना आगाऊ खरेदी ऑर्डर आवश्यक आहे. कृपया तुमच्या प्रादेशिक C शी संपर्क साधाampतपशीलासाठी वैज्ञानिक कार्यालयाची घंटी.

सुरक्षितता
धोका — ट्रायपॉड्स, टॉवर्स, आणि ट्रायपॉड्स आणि टॉवर्सना सेन्सर्स, इरॉसेन्टसीक्लर्स यांसारख्या कोणत्याही संलग्नकांना स्थापित करणे, वापरणे, देखरेख करणे आणि त्यांच्याभोवती काम करणे यासह अनेक धोके संबंधित आहेत. ट्रायपॉड्स, टॉवर्स आणि संलग्नक योग्यरित्या आणि पूर्णपणे एकत्र करण्यात अयशस्वी होणे, स्थापित करणे, ऑपरेट करणे, वापरणे आणि राखणे, आणि चेतावणींचे पालन करण्यात अयशस्वी होणे, मृत्यूचा धोका वाढवते, प्रॉडक्ट, प्रॉडक्ट AILURE. हे धोके टाळण्यासाठी सर्व वाजवी खबरदारी घ्या. कोणतेही काम करण्यापूर्वी कार्यपद्धती आणि आवश्यक संरक्षणात्मक उपकरणे यासाठी तुमच्या संस्थेच्या सुरक्षा समन्वयकाकडे (किंवा धोरण) तपासा.
ट्रायपॉड्स, टॉवर्स आणि ट्रायपॉड्स आणि टॉवर्सच्या संलग्नकांचा वापर फक्त त्या हेतूंसाठी करा ज्यासाठी ते डिझाइन केले आहेत. डिझाइन मर्यादा ओलांडू नका. परिचित व्हा आणि उत्पादन मॅन्युअलमध्ये दिलेल्या सर्व सूचनांचे पालन करा. मॅन्युअल www.c वर उपलब्ध आहेतampbellsci.com सुरक्षेचे नियम आणि टॉवर्स, ट्रायपॉड्स आणि कोणत्याही संलग्नकांना संलग्न केलेल्या संरचनेची किंवा जमिनीची अखंडता आणि स्थान यासह प्रशासकीय संहिता आणि नियमांचे पालन करण्यासाठी तुम्ही जबाबदार आहात. इन्स्टॉलेशन साइट्सचे मूल्यमापन आणि पात्र अभियंत्याने मंजूर केले पाहिजे. ट्रायपॉड्स, टॉवर्स, अटॅचमेंट्स किंवा इलेक्ट्रिकल कनेक्शन्सची स्थापना, वापर किंवा देखभाल करण्याबाबत प्रश्न किंवा समस्या उद्भवल्यास, परवानाधारक आणि पात्र अभियंता किंवा इलेक्ट्रिशियनचा सल्ला घ्या.
सामान्य l ओव्हर-व्हॉल्यूमपासून संरक्षण कराtage l विद्युत उपकरणांचे पाण्यापासून संरक्षण करा. l इलेक्ट्रोस्टॅटिक डिस्चार्ज (ESD) पासून संरक्षण करा. l विजेपासून संरक्षण करा. l साइट किंवा इन्स्टॉलेशनचे काम करण्यापूर्वी, आवश्यक मंजूरी आणि परवानग्या मिळवा. यूएसए मधील FAA सारख्या सर्व शासित संरचना-उंची नियमांचे पालन करा. l ट्रायपॉड्स आणि टॉवर्सची स्थापना, वापर आणि देखभाल करण्यासाठी आणि ट्रायपॉड्स आणि टॉवर्सच्या कोणत्याही संलग्नकांसाठी केवळ पात्र कर्मचारी वापरा. परवानाधारक आणि पात्र कंत्राटदारांचा वापर अत्यंत शिफारसीय आहे. l सर्व लागू सूचना काळजीपूर्वक वाचा आणि कार्य सुरू करण्यापूर्वी प्रक्रिया पूर्णपणे समजून घ्या. l ट्रायपॉड्स आणि टॉवर्सवर किंवा त्याच्या आजूबाजूला काम करताना हार्डहाट आणि डोळ्यांचे संरक्षण घाला आणि इतर योग्य सुरक्षा खबरदारी घ्या. l ट्रायपॉड किंवा टॉवर कधीही चढू नका आणि इतर व्यक्तींना चढण्यास मनाई करा. ट्रायपॉड आणि टॉवर साइट्स अतिक्रमण करणाऱ्यांपासून सुरक्षित करण्यासाठी वाजवी खबरदारी घ्या. l केवळ निर्मात्याने शिफारस केलेले भाग, साहित्य आणि साधने वापरा.
युटिलिटी आणि इलेक्ट्रिकल l ट्रायपॉड, टॉवर किंवा तुम्ही स्थापित करत असलेले, बांधत असलेले, वापरत असलेले किंवा देखभाल करत असलेले किंवा एखादे साधन, स्टेक किंवा अँकर ओव्हरहेड किंवा भूमिगत युटिलिटी लाईन्सच्या संपर्कात आल्यास तुम्हाला मारले जाऊ शकते किंवा गंभीर शारीरिक इजा होऊ शकते. . l ओव्हरहेड युटिलिटी लाईन्स आणि स्ट्रक्चर (ट्रायपॉड, टॉवर, संलग्नक) यांच्यातील किमान दीडपट उंची, 6 मीटर (20 फूट), किंवा लागू कायद्यानुसार आवश्यक असलेले अंतर, यापैकी जे जास्त असेल ते ठेवा. , किंवा साधने). l साइट किंवा इंस्टॉलेशनचे काम करण्यापूर्वी, सर्व युटिलिटी कंपन्यांना सूचित करा आणि सर्व भूमिगत उपयुक्तता चिन्हांकित करा. l सर्व इलेक्ट्रिकल कोडचे पालन करा. इलेक्ट्रिकल उपकरणे आणि संबंधित ग्राउंडिंग उपकरणे परवानाधारक आणि पात्र इलेक्ट्रिशियनद्वारे स्थापित केली जावीत. l स्थापनेच्या देशात वापरण्यासाठी मंजूर केलेल्या उर्जा स्त्रोतांचा वापर करा Campघंटा वैज्ञानिक उपकरणे.
भारदस्त काम आणि हवामान l भारदस्त काम करताना अत्यंत सावधगिरी बाळगा. l योग्य उपकरणे आणि सुरक्षा पद्धती वापरा. l स्थापना आणि देखभाल दरम्यान, टॉवर आणि ट्रायपॉड साइट्स अप्रशिक्षित किंवा अत्यावश्यक कर्मचाऱ्यांपासून दूर ठेवा. भारदस्त साधने आणि वस्तू खाली पडू नयेत यासाठी खबरदारी घ्या. l वारा, पाऊस, बर्फ, विजा इत्यादींसह प्रतिकूल हवामानात कोणतेही काम करू नका.
अंतर्गत बॅटरी l आग, स्फोट आणि गंभीर जळण्याच्या धोक्यांपासून सावध रहा. l अंतर्गत लिथियम बॅटरीचा गैरवापर किंवा अयोग्य स्थापना केल्याने गंभीर इजा होऊ शकते.

l रिचार्ज करू नका, वेगळे करू नका, 100 °C (212 °F) पेक्षा जास्त उष्णता देऊ नका, थेट सेलमध्ये सोल्डर करू नका, जाळू नका किंवा त्यातील सामग्री पाण्यामध्ये उघड करू नका. खर्च झालेल्या बॅटरीची योग्य प्रकारे विल्हेवाट लावा.
बॅटरीजचा वापर आणि विल्हेवाट लावणे l जेथे बॅटरी इंस्टॉलेशन साइटवर नेणे आवश्यक आहे, तेथे बॅटरी टर्मिनल्स कमी होण्यापासून रोखण्यासाठी त्या पॅक केल्या आहेत याची खात्री करा ज्यामुळे आग किंवा स्फोट होऊ शकतो. विशेषत: लिथियम बॅटरीच्या बाबतीत, ते स्थानिक शिपिंग नियमांचे आणि त्यात समाविष्ट असलेल्या वाहकांच्या सुरक्षा आवश्यकतांचे पालन करतात अशा प्रकारे ते पॅक आणि वाहतूक केले आहेत याची खात्री करा. l बॅटरी इन्स्टॉल करताना इंस्टॉलेशनच्या सूचनांचे काळजीपूर्वक पालन करा. चुकीच्या प्रकारची बॅटरी किंवा रिव्हर्स कनेक्शन स्थापित केल्यामुळे उपकरणांचे नुकसान होण्याचा धोका टाळण्यासाठी हे आहे. l वापरलेल्या बॅटरीची विल्हेवाट लावताना, शॉर्टिंगचा धोका टाळणे अजूनही महत्त्वाचे आहे. आगीत बॅटरीची विल्हेवाट लावू नका कारण स्फोट होण्याचा आणि पर्यावरणात हानिकारक रसायनांची गळती होण्याचा धोका असतो. नोंदणीकृत पुनर्वापर सुविधांमध्ये बॅटरीची विल्हेवाट लावली पाहिजे.
रेडिओ ट्रान्समीटर रेडिएशनचा अनावश्यक संपर्क टाळणे l जेथे उपकरणांमध्ये रेडिओ ट्रान्समीटर समाविष्ट आहे, तेथे अँटेनामधून रेडिएशनचा अनावश्यक संपर्क टाळण्यासाठी खबरदारी घेतली पाहिजे. आवश्यक सावधगिरीची डिग्री ट्रान्समीटरच्या सामर्थ्यानुसार बदलते, परंतु नियम म्हणून अँटेना सक्रिय असताना 20 सेमी (8 इंच) पेक्षा अँटेना जवळ जाणे टाळणे चांगले. विशेषतः तुमचे डोके अँटेनापासून दूर ठेवा. उच्च पॉवर रेडिओसाठी (1 W ERP पेक्षा जास्त) सिस्टम सर्व्हिस करताना रेडिओ बंद करा, जोपर्यंत अँटेना स्टेशनपासून दूर स्थापित केला जात नाही, उदा. तो सिस्टमच्या वर हातावर किंवा खांबावर बसवला जातो.
देखभाल l वेळोवेळी (किमान वार्षिक) पोशाख आणि नुकसान तपासा, ज्यामध्ये गंज, तणाव, तडे, तळलेले केबल्स, सैल केबलamps, केबल घट्टपणा इ. आणि आवश्यक सुधारात्मक कृती करा. l वेळोवेळी (किमान वार्षिक) विद्युत ग्राउंड कनेक्शन तपासा.
सर्व C मध्ये सुरक्षिततेची सर्वोच्च पदवी प्राप्त करण्याचा प्रत्येक प्रयत्न केला जात असतानाAMPBELL वैज्ञानिक उत्पादने, ट्रायपॉड्स, टॉवर्स किंवा ट्रायपॉड्स, टॉवर्स, सेंट्सरॉसर्सवेअर्स, इंद्रियसंस्कार, यंत्रसामग्री यांच्याशी संलग्नकांची अयोग्य स्थापना, वापर किंवा देखभाल यामुळे होणार्‍या कोणत्याही दुखापतीपासून सर्व जोखीम ग्राहक गृहीत धरतात.

Campघंटा वैज्ञानिक प्रादेशिक कार्यालये

ऑस्ट्रेलिया

स्थान: फोन: ईमेल: Webसाइट:

Garbutt, QLD ऑस्ट्रेलिया 61.7.4401.7700 info@campbellsci.com.au www.campbellsci.com.au

ब्राझील
स्थान: फोन: ईमेल: Webसाइट:

साओ पाउलो, SP ब्राझील 11.3732.3399 vendas@campbellsci.com.br www.campbellsci.com.br

कॅनडा
स्थान: फोन: ईमेल: Webसाइट:

एडमंटन, एबी कॅनडा 780.454.2505 dataloggers@campbellsci.ca www.campbellsci.ca

चीन
स्थान: फोन: ईमेल: Webसाइट:

बीजिंग, PR चीन 86.10.6561.0080 info@campbellsci.com.cn www.campbellsci.com.cn

कोस्टा रिका

स्थान: फोन: ईमेल: Webसाइट:

सॅन पेड्रो, कोस्टा रिका 506.2280.1564 info@campbellsci.cc www.campbellsci.cc

फ्रान्स
स्थान: फोन: ईमेल: Webसाइट:

मॉन्ट्रोज, फ्रान्स 0033.0.1.56.45.15.20 info@campbellsci.fr www.campbellsci.fr

जर्मनी

स्थान: फोन: ईमेल: Webसाइट:

ब्रेमेन, जर्मनी 49.0.421.460974.0 info@campbellsci.de www.campbellsci.de

भारत
स्थान: फोन: ईमेल: Webसाइट:

नवी दिल्ली, DL भारत 91.11.46500481.482 info@campbellsci.in www.campbellsci.in

जपान
स्थान: फोन: ईमेल: Webसाइट:

कावागिशी, तोडा शहर, जपान 048.400.5001 jp-info@campbellsci.com www.campbellsci.co.jp

दक्षिण आफ्रिका

स्थान: फोन: ईमेल: Webसाइट:

Stellenbosch, दक्षिण आफ्रिका 27.21.8809960 sales@campbellsci.co.za www.campbellsci.co.za

स्पेन
स्थान: फोन: ईमेल: Webसाइट:

बार्सिलोना, स्पेन ३४.९३.२३२३९३८ info@campbellsci.es www.campbellsci.es

थायलंड

स्थान: फोन: ईमेल: Webसाइट:

बँकॉक, थायलंड 66.2.719.3399 info@campbellsci.asia www.campbellsci.asia

UK
स्थान: फोन: ईमेल: Webसाइट:

शेपशेड, लॉफबरो, यूके 44.0.1509.601141 sales@campbellsci.co.uk www.campbellsci.co.uk

यूएसए
स्थान: फोन: ईमेल: Webसाइट:

लोगान, यूटी यूएसए 435.227.9120 info@campbellsci.com www.campbellsci.com

कागदपत्रे / संसाधने

Campबेल सायंटिफिक रेंजव्ह्यू सिरीज रडार वॉटर लेव्हल सेन्सर्स [pdf] सूचना पुस्तिका
RangeVue 15, RangeVue 30, RangeVue Series Radar Water Level Sensors, RangeVue Series, Radar Water Level Sensors, Water Level Sensors, Level Sensors, Sensors

संदर्भ

एक टिप्पणी द्या

तुमचा ईमेल पत्ता प्रकाशित केला जाणार नाही. आवश्यक फील्ड चिन्हांकित आहेत *