Sonew -100L

Sonew Invisible Beam Barrier Infrared Motion Detector

Model: -100L Instruction Manual

Brand: Sonew

1. परिचय

The Sonew Invisible Beam Barrier Infrared Motion Detector, Model -100L, is designed to provide reliable perimeter security through active digital pulse infrared detection. This system is suitable for various applications including homes, driveways, farms, and factories, offering intelligent detection and adaptability to diverse environments.

The device features a smart chip that automatically adjusts transmit power based on environmental conditions, extending product lifespan and reducing power consumption. Its robust, integrated sealing structure with an IP55 rating ensures waterproof and tamper-proof operation, making it suitable for outdoor use in various weather conditions.

2. पॅकेज सामग्री

खाली सूचीबद्ध केलेल्या सर्व वस्तू तुमच्या पॅकेजमध्ये समाविष्ट आहेत याची खात्री करा:

  • 1 x ट्रान्समीटर युनिट
  • 1 x प्राप्तकर्ता युनिट
  • 3 एक्स आरोहित कंस
  • 4 x स्क्रू

3. तपशील

वैशिष्ट्यतपशील
मॉडेल-100L
साहित्यABS
रंगकाळा
अलार्म आउटपुटNC and NO rating AV/DC 30V, 0.5A
शोध पद्धतCovers the light at the same time
चेतावणी अंतर100 मी / 328 फूट
प्रकाश स्रोतDigital pulse infrared
Induction Rate50-700ms
Horizontal Adjustment Axis180° ± 90°
Vertical Adjustment Axis±10°
इनपुट व्हॉल्यूमtageDC 12-24V, AC 11-18V
कार्यरत वर्तमान100mA
वजन723g / 25.5oz (approx. 1.55 lbs)
उत्पादन परिमाणे17 x 8.2 x 8 सेमी / 6.7 x 3.2 x 3.1 इंच

4. सेटअप

Proper installation and alignment are crucial for optimal performance of your Invisible Beam Barrier.

4.1. माउंटिंग

The system consists of two units: a transmitter and a receiver. These units must be installed facing each other with a clear line of sight to create the invisible beam. Ensure the mounting surface is stable and secure.

  1. स्थान निवडा: Select a location where the beam will cover the desired detection area. Ensure there are no permanent obstructions between the transmitter and receiver.
  2. उंची: Install both the transmitter and receiver at least 20cm (approximately 8 inches) above the ground to avoid false alarms from small animals or debris.
  3. छिद्रे चिन्हांकित करा: Use the provided mounting brackets to mark the drilling points on your chosen surface.
  4. Drill & Secure: Drill the marked holes and securely attach the brackets using the provided screws. For enhanced stability, consider placing a rubber pad (not included) between the sensor and the mounting surface.
  5. Attach Units: Mount the transmitter and receiver units onto their respective brackets.
Sonew Invisible Beam Barrier Transmitter and Receiver Units

Image: The transmitter and receiver units of the Sonew Invisible Beam Barrier.

Sonew Invisible Beam Barrier Dimensions

Image: Dimensions of the Sonew Invisible Beam Barrier units.

Sonew Invisible Beam Barrier Outdoor Installation Example

प्रतिमा: उदाample of outdoor installation for the Sonew Invisible Beam Barrier.

4.2. वायरिंग

Connect the power supply and alarm output wires according to the diagram below. Ensure all connections are secure and insulated.

  1. वीज कनेक्शन: Connect the power wires to the DC 12-24V or AC 11-18V power source. Refer to the unit's terminals for positive and negative connections.
  2. अलार्म आउटपुट: Connect the alarm output wires (NC/NO) to your alarm system's input. The alarm output is rated AV/DC 30V, 0.5A.

Video: This video demonstrates the wiring and installation process for a similar infrared photocell sensor, including connecting to power and a control board. It shows how to remove housings, connect 2-core and 4-core wires, and power the sensors.

4.3. संरेखन

Accurate alignment between the transmitter and receiver is critical for the system's effectiveness.

  1. प्रारंभिक पॉवर-अप: After wiring, power on both units. Observe the LED indicators on the units.
  2. Rough Alignment: Visually align the transmitter and receiver so they are generally pointing at each other.
  3. Fine Alignment: Use the horizontal (180° ± 90°) and vertical (±10°) adjustment axes to fine-tune the alignment. The receiver unit typically has an indicator (e.g., an OFF LED) that will turn off or change color when a strong, clear beam is detected. Adjust until this indicator confirms optimal alignment.
  4. चाचणी: Once aligned, test the system by breaking the beam to ensure the alarm triggers correctly.
Sonew Invisible Beam Barrier Infrared Beam Illustration

Image: Illustration of the infrared beam between the transmitter and receiver units, demonstrating the 100m range.

5. ऑपरेटिंग सूचना

The Sonew Invisible Beam Barrier operates automatically once properly installed and aligned.

  1. बुद्धिमान शोध: The system continuously emits a digital pulse infrared beam. When this beam is interrupted by an object or person, the receiver detects the change.
  2. अलार्म ट्रिगर: Upon detection of a broken beam, the receiver activates its alarm output (NC/NO), which can be connected to a siren, security panel, or other alert system. The induction rate is 50-700ms, ensuring quick response.
  3. पर्यावरणीय अनुकूलता: The intelligent chip automatically adjusts the radio's transmit power based on environmental conditions, maintaining performance and extending the life of the launch tube.

6. देखभाल

Regular maintenance helps ensure the longevity and reliable operation of your beam barrier system.

  • लेन्स स्वच्छ करा: Periodically clean the lenses of both the transmitter and receiver units with a soft, damp धूळ, घाण किंवा कोळी काढण्यासाठी कापडwebs that could obstruct the beam and cause false alarms.
  • संरेखन तपासा: Verify that the units remain properly aligned, especially after strong winds or physical impacts. Re-align if necessary.
  • वायरिंगची तपासणी करा: Check all wiring connections for corrosion, damage, or loose terminals. Ensure they are secure and protected from the elements.
  • हवामान संरक्षण: The IP55 rating provides protection against dust and water jets. However, extreme weather conditions may still affect performance. Ensure units are not submerged in water.
Sonew Invisible Beam Barrier IP55 Weatherproof Rating

Image: The IP55 weatherproof rating of the Sonew Invisible Beam Barrier, highlighting its integrated sealing structure.

7. समस्या निवारण

If you encounter issues with your Invisible Beam Barrier, refer to the following common problems and solutions:

  • No Alarm Triggered:
    • Check power supply to both units.
    • Verify proper alignment of transmitter and receiver.
    • Ensure alarm output wires are correctly connected to your alarm system.
    • Clean the lenses for any obstructions.
  • खोटे अलार्म:
    • Check for any moving objects (e.g., swaying branches, large animals) that might intermittently break the beam.
    • Re-align the units precisely to minimize interference.
    • Ensure units are mounted at the recommended height (at least 20cm above ground).
    • Clean the lenses thoroughly.
  • Power Indicator Off:
    • Check the power source and all power connections.
    • योग्य व्हॉल्यूमची खात्री कराtage (DC 12-24V, AC 11-18V) is supplied.

8. हमी आणि समर्थन

वॉरंटी माहिती, तांत्रिक समर्थन किंवा सेवा चौकशीसाठी, कृपया तुमच्या किरकोळ विक्रेत्याशी किंवा उत्पादकाशी थेट संपर्क साधा. खरेदीचा पुरावा म्हणून तुमची खरेदी पावती ठेवा.

संबंधित कागदपत्रे - -100L

प्रीview Focus ABH Series 4-Beam Active Photoelectric Intruder Detector Installation Guide
Comprehensive installation guide for the Focus ABH series 4-beam active photoelectric intruder detectors. Covers model specifications, precautions, setting procedures, beam alignment, response time adjustment, physical testing, troubleshooting, and technical parameters.
प्रीview DN-50 Electric Milk Separator: Instructions and Operation Guide
Comprehensive instructions for the DN-50 Electric Milk Separator, covering installation, operation, milk fat concentration adjustment, cleaning, troubleshooting, and important notes for optimal use.
प्रीview Руководство по эксплуатации ременного компрессора INFORCE
Полное руководство по эксплуатации ременных компрессоров INFORCE, охватывающее назначение, технические характеристики, безопасность, подготовку, эксплуатацию, техническое обслуживание, устранение неисправностей, транспортировку, хранение и гарантийные условия для различных моделей.
प्रीview विल्सन क्लॅश १०० एल व्ही२ टेनिस रॅकेट स्ट्रिंगिंग सूचना
विल्सन क्लॅश १०० एल व्ही२ टेनिस रॅकेटसाठी स्ट्रिंगिंगच्या तपशीलवार सूचना, ज्यामध्ये स्ट्रिंग पॅटर्न, लांबी, टेंशन शिफारसी आणि विशिष्ट टाय-ऑफ पॉइंट्स समाविष्ट आहेत.
प्रीview Bradford White D-Series Flue Damper Electronic Ignition Commercial Gas Water Heater Datasheet
Detailed specifications, features, and performance data for the Bradford White D-Series Flue Damper Electronic Ignition Commercial Gas Water Heaters, including recovery rates, dimensions, and optional equipment.
प्रीview ZIPPER ZI-EWB150-100L Elektrische Schubkarre Bedienungsanleitung
Umfassende Bedienungsanleitung für die ZIPPER ZI-EWB150-100L Elektrische Schubkarre. Enthält Informationen zu Sicherheit, Montage, Betrieb, Wartung und Fehlerbehebung.