1. परिचय
Thank you for choosing the FORA Painless Design Adjustable Lancing Device. This device is designed to assist in obtaining blood samples for glucose monitoring with enhanced comfort and safety. Please read this manual thoroughly before using the device to ensure proper operation and to understand all safety precautions.
प्रमुख वैशिष्ट्ये:
- समायोज्य खोली सेटिंग्ज: Offers 6 dial-in-click depth settings for personalized comfort based on skin type.
- Safe Lancet Ejection: Features a built-in ejector mechanism for hygienic removal of used lancets without direct contact.
- पर्यायी साइट चाचणी: Includes a clear end cap for testing on alternative sites such as the forearm or palm.
- सुसंगतता: Compatible with most standard lancets (lancets sold separately).
2. सुरक्षितता माहिती
Always follow basic safety precautions when using this lancing device to reduce the risk of injury or infection.
- For Single Patient Use Only: This lancing device is intended for use by a single individual. Sharing the device can lead to the transmission of bloodborne pathogens.
- Use New Lancets: Always use a new, sterile lancet for each test. Reusing lancets can cause infection and dull the tip, leading to increased pain.
- योग्य विल्हेवाट: Dispose of used lancets in an approved sharps container immediately after use.
- मुलांच्या आवाक्याबाहेर ठेवा: Store the lancing device and lancets safely away from children.
- आरोग्यसेवा व्यावसायिकांचा सल्ला घ्या: Statements regarding dietary supplements have not been evaluated by the FDA and are not intended to diagnose, treat, cure, or prevent any disease or health condition. Always consult with a healthcare professional for medical advice.
3. उत्पादन संपलेview
Familiarize yourself with the components of your FORA Lancing Device:

आकृती 3.1: Components of the FORA Lancing Device. This diagram illustrates the main parts: the protective cap, the depth indicator for setting penetration level, the ejector mechanism for safe lancet removal, and the release button to activate the lancing action.
- कॅप: The protective cover that twists off to access the lancet chamber.
- खोली निर्देशक: A dial with 6 settings to adjust the lancet penetration depth.
- इजेक्टर: A mechanism to safely remove used lancets without direct handling.
- रिलीझ बटण: The button pressed to activate the lancing action.
- Lancing Device Body: The main housing of the device.
4. सेटअप
4.1 Inserting a Lancet
- Unscrew the cap from the lancing device.
- Insert a new, sterile lancet firmly into the lancet holder.
- Twist off the protective cap from the lancet. Retain this cap for safe disposal later.
- Replace the lancing device cap by screwing it back on.
4.2 Adjusting Penetration Depth
The lancing device features 6 adjustable depth settings. Rotate the cap to select the desired depth. A higher number indicates a deeper penetration.
- सेटिंग्ज 1-2: For soft or thin skin.
- सेटिंग्ज 3-4: For average skin.
- सेटिंग्ज 5-6: For thick or calloused skin.

आकृती 4.1: Steps for preparing and using the lancing device. This image demonstrates selecting the penetration depth, cocking the device, and performing a finger prick.
5. ऑपरेटिंग सूचना
5.1 Performing a Blood Sample (Fingerstick)
- तुमचे हात साबणाने आणि कोमट पाण्याने चांगले धुवा, नंतर ते पूर्णपणे कोरडे करा.
- Ensure a new lancet is inserted and the depth setting is appropriate for your skin type (refer to Section 4.2).
- Pull the cocking control back until it clicks. The device is now armed.
- लान्सिंग डिव्हाइस आपल्या बोटाच्या टोकाच्या बाजूला घट्टपणे ठेवा.
- Press the release button to activate the lancet.
- Gently massage your finger from the base towards the tip to form a blood drop. Do not squeeze excessively.
- Apply the blood drop to your glucose meter test strip as instructed by your meter's manual.
5.2 Alternative Site Testing (AST)
The FORA Lancing Device includes a clear alternate site end cap for testing on areas other than the fingertip, such as the forearm or palm. Consult your healthcare professional before performing AST, as results from alternative sites may differ from fingertip results, especially during periods of rapid glucose change.
- Remove the standard cap and replace it with the clear AST cap.
- Select a suitable depth setting (AST generally requires a deeper setting due to thicker skin).
- Pull the cocking control back until it clicks.
- Press the clear AST cap firmly against the chosen alternative site (e.g., forearm or palm) and hold for a few seconds to create a vacuum.
- प्रकाशन बटण दाबा.
- Gently massage the area to form a blood drop.
- Apply the blood drop to your glucose meter test strip.
5.3 Safely Disposing of a Used Lancet
Proper disposal of used lancets is crucial to prevent accidental needle sticks and the spread of infection.

आकृती 5.1: Steps for safe lancet disposal. This image shows how to cap the lancet and then use the ejector mechanism to remove it from the device.
- लान्सिंग डिव्हाइस कॅप अनस्क्रू करा.
- Carefully place the protective cap (removed in Section 4.1) back onto the used lancet, ensuring the needle is fully covered. Alternatively, if your lancets come with a protective disk, push the exposed tip into the disk on a hard surface.
- Slide the ejector forward to release the capped lancet into an approved sharps container.
- लॅन्सिंग डिव्हाइस कॅप बदला.
6. देखभाल
6.1 Cleaning the Lancing Device
- Clean the exterior of the lancing device regularly with a soft cloth dampसौम्य साबण आणि पाण्याने समाप्त.
- उपकरण पाण्यात किंवा कोणत्याही स्वच्छतेच्या द्रावणात बुडवू नका.
- साठवण्यापूर्वी किंवा पुढील वापरण्यापूर्वी उपकरण पूर्णपणे कोरडे असल्याची खात्री करा.
५.८.१ स्टोरेज
- Store the lancing device in a clean, dry place at room temperature.
- अति तापमान, थेट सूर्यप्रकाश आणि जास्त आर्द्रता टाळा.
- Keep the device and all accessories out of reach of children and pets.
7. समस्या निवारण
If you encounter issues with your lancing device, refer to the table below for common problems and solutions.
| समस्या | संभाव्य कारण | उपाय |
|---|---|---|
| Device does not cock or fire. | Device not fully cocked; lancet not inserted correctly; device malfunction. | Ensure the cocking control is pulled back until it clicks. Re-insert lancet. If problem persists, contact customer support. |
| अपुरे रक्त एसampले | Depth setting too shallow; insufficient blood flow; cold hands. | Increase depth setting. Warm hands before testing. Gently massage the lanced area. |
| Pain during lancing. | Depth setting too deep; reused lancet; lancing on calloused area. | Decrease depth setting. Always use a new lancet. Choose a different lancing site. |
| Lancet cannot be ejected. | Lancet stuck; ejector mechanism obstructed. | Ensure the cap is removed. Gently try to slide the ejector. If stuck, carefully remove with tweezers and dispose of safely. |
8. तपशील
| वैशिष्ट्य | तपशील |
|---|---|
| मॉडेल | Painless Design Adjustable Lancing Device |
| खोली सेटिंग्ज | 6 समायोज्य पातळी |
| लॅन्सेट सुसंगतता | Most standard lancets (28-33 gauge) |
| परिमाण | अंदाजे 6.1 x 3.2 x 1 इंच |
| वजन | अंदाजे 1.6 औंस |
| उत्पादक | ForaCare Inc. |
| ASIN | B01INS8T5I |
9. हमी आणि समर्थन
For warranty information, technical support, or to purchase accessories, please contact FORA customer service or visit the official FORA webसाइट
You can find more information about FORA products and support at the FORA Store on Amazon.