1. परिचय
The DSC SS102 Seismic Vibration Sensor is designed to detect shock and vibration, providing an essential layer of security for various applications. This manual provides detailed instructions for the proper installation, operation, and maintenance of the SS102 sensor to ensure optimal performance and reliability within your security system.
2. प्रमुख वैशिष्ट्ये
- Seismic vibration detection for enhanced security.
- Adjustable pulse count for false alarm prevention.
- Integrated LED indicator for status and testing.
- Suitable for indoor shock/vibration detection.
- Surface mount installation.
3. सुरक्षितता माहिती
Please read all instructions carefully before installing or operating the DSC SS102 sensor. Failure to follow these instructions may result in improper operation, damage to the device, or personal injury.
- स्थापना केवळ पात्र कर्मचार्यांनीच केली पाहिजे.
- Disconnect power to the control panel before performing any wiring or maintenance.
- Ensure all wiring connections are secure and correct according to the control panel's specifications.
- Do not expose the sensor to extreme temperatures or moisture beyond its specified operating conditions.
- हे उपकरण केवळ घरातील वापरासाठी आहे.
4. स्थापना आणि सेटअप
Proper installation is crucial for the optimal performance of the SS102 sensor. Follow these steps carefully:
4.1 माउंटिंग स्थान
- Select a solid, stable surface that is directly connected to the area you wish to protect (e.g., a wall, window frame, or safe).
- Avoid mounting on surfaces that are prone to excessive vibration from non-security related sources (e.g., heavy machinery, air conditioning units).
- माउंटिंग पृष्ठभाग स्वच्छ आणि कोरडे असल्याची खात्री करा.
4.2 भौतिक स्थापना
- Carefully open the sensor casing to access mounting holes and terminals.
- Using appropriate screws, securely mount the sensor to the chosen surface. Ensure it is firmly attached to transmit vibrations effectively.
- Refer to the diagram below for typical mounting orientation and component identification.

आकृती 1: DSC SS102 Seismic Vibration Sensor. This image shows the white rectangular sensor unit. Visible on its front face are the "DSC" logo, the word "SHOCKGUARD" embossed vertically, a small adjustment screw, and an LED indicator. The sensor is designed for surface mounting.
4.3 वायरिंग
Connect the sensor to your alarm control panel according to the panel's instructions and the SS102 wiring terminals. Typically, this involves connecting to a zone input and power supply.
- Identify the alarm output terminals and power input terminals on the SS102.
- Connect the power supply (e.g., 12V DC) to the designated power terminals.
- Connect the alarm output to a supervised zone input on your control panel.
- Ensure proper polarity for power connections.
4.4 Sensitivity and Pulse Count Adjustment
The SS102 features adjustable sensitivity and pulse count to prevent false alarms while ensuring reliable detection.
- संवेदनशीलता समायोजन: Use a small screwdriver to adjust the sensitivity screw (refer to Figure 1). Turn clockwise to increase sensitivity, counter-clockwise to decrease. Test the sensor after each adjustment.
- नाडी संख्या: The pulse count setting determines how many consecutive shock events are required within a short period to trigger an alarm. This helps differentiate between genuine threats from minor environmental disturbances. Consult your control panel or sensor documentation for specific pulse count settings if available, or adjust based on thorough testing.
5. ऑपरेशन
Once installed and configured, the DSC SS102 sensor continuously monitors for seismic vibrations. When the detected vibration level exceeds the set sensitivity threshold for the specified pulse count, the sensor will trigger an alarm condition, signaling the connected control panel.
- एलईडी निर्देशक: The integrated LED (refer to Figure 1) provides visual feedback during testing and operation. It typically illuminates briefly upon detection of a shock event, and may indicate an alarm condition depending on the system's configuration.
- चाचणी: Regularly test the sensor by applying controlled impacts to the protected surface (e.g., tapping firmly near the sensor) to ensure it triggers an alarm at the desired sensitivity level.
6. देखभाल
The DSC SS102 sensor requires minimal maintenance to ensure long-term reliability.
- स्वच्छता: Periodically wipe the sensor's exterior with a soft, dry cloth to remove dust. Do not use abrasive cleaners or solvents, as these may damage the casing किंवा अंतर्गत घटक.
- चाचणी: Perform functional tests at least annually, or more frequently in high-security applications, to verify proper operation and sensitivity settings.
- पर्यावरण तपासणी: Ensure the sensor remains free from moisture, extreme temperatures, and physical damage.
7. समस्या निवारण
| समस्या | संभाव्य कारण | उपाय |
|---|---|---|
| Sensor not triggering | Low sensitivity setting, improper wiring, power issue, faulty sensor. | Increase sensitivity, check wiring connections to the control panel, verify power supply, test sensor functionality. |
| खोटे गजर | High sensitivity setting, low pulse count, environmental vibrations, improper mounting. | Decrease sensitivity, increase pulse count, relocate sensor if necessary, ensure secure mounting to a stable surface. |
| एलईडी प्रकाशित होत नाही | No power, faulty LED, sensor not detecting events. | Check power connections, test sensor for detection by applying a shock, contact support if LED remains non-functional. |
8. तपशील
| वैशिष्ट्य | तपशील |
|---|---|
| मॉडेल | SS102 |
| ब्रँड | DSC |
| माउंटिंग प्रकार | पृष्ठभाग माउंट |
| आउटपुट प्रकार | Electrical signal |
| विशिष्ट उपयोग | Indoor shock/vibration detection |
| उच्च तापमान रेटिंग | 120°F (49°C) |
| आयटम मॉडेल क्रमांक | SS102 |
9. हमी आणि समर्थन
For warranty information and technical support, please refer to the documentation provided with your purchase or contact your authorized DSC dealer or distributor. Keep your proof of purchase for warranty claims.
For further assistance, visit the official DSC webसाइट किंवा त्यांच्या ग्राहक सेवा विभागाशी संपर्क साधा.