EVTSCAN B0CF3V9SFX

EVTSCAN Soil Tester User Manual

Model: B0CF3V9SFX

परिचय

This manual provides detailed instructions for the proper use and maintenance of your EVTSCAN Soil Tester. Please read this manual thoroughly before operating the device to ensure accurate measurements and prolonged product life. This device is designed for measuring soil temperature, air temperature, air humidity, and illumination levels in various environments such as plants, gardens, lawns, and farms.

उत्पादन संपलेview

The EVTSCAN Soil Tester is a portable device designed for quick and accurate environmental measurements. It features a clear display, easy-to-use buttons, and a durable probe.

समोर view of the EVTSCAN Soil Tester, showing the display, buttons, and probe.

आकृती 1: समोर view of the EVTSCAN Soil Tester.

प्रमुख वैशिष्ट्ये:

  • वापरण्यास सोपा: Obtain test results quickly by inserting the probe into the soil.
  • अचूक मापन: Designed for precise readings of environmental conditions.
  • Data Lock Function: A dedicated HOLD button allows for convenient data viewing
  • पोर्टेबल डिझाइन: Compact and lightweight for easy transport and use in various locations.
  • बहुमुखी अनुप्रयोग: Suitable for family plants, gardens, lawns, and farms.

सेटअप

बॅटरी स्थापना:

  1. डिव्हाइसच्या मागील बाजूस बॅटरी कंपार्टमेंट शोधा.
  2. बॅटरी कंपार्टमेंट कव्हर उघडा.
  3. Remove any packaging from the included 9V 6F22 dry battery.
  4. Insert the 9V battery, ensuring correct polarity.
  5. बॅटरी कंपार्टमेंट कव्हर सुरक्षितपणे बंद करा.
मागे view of the EVTSCAN Soil Tester, showing the battery compartment.

आकृती ३: बॅटरी कंपार्टमेंटचे स्थान.

Note: The device will not power on until the battery is correctly installed and any protective film is removed from the battery terminals.

ऑपरेटिंग सूचना

डिव्हाइस नियंत्रणे:

Close-up of the EVTSCAN Soil Tester's control buttons: ON/OFF, C/F, and HOLD.

Figure 3: Control buttons on the EVTSCAN Soil Tester.

  • चालू/बंद बटण:
    • Short press to turn the device on.
    • Long press for 3 seconds to turn the device off.
    • The device will automatically turn off after 15 minutes of inactivity to conserve battery life.
  • ℃/℉ बटण:
    • Press this button to switch the temperature unit between Celsius (℃) and Fahrenheit (℉).
  • बटण दाबून ठेवा:
    • Press this button to lock the current readings on the display. This is useful for recording data.
    • Press again to release the data lock and resume live readings.

मोजमाप घेणे:

  1. Turn on the device by short pressing the चालू/बंद बटण
  2. Insert the metal probe into the soil to approximately 2/3 of its length (about 14-15 cm or 5.5-6 inches). Ensure the probe is fully inserted into the root zone for accurate soil readings.
  3. Position the device to face the sun for accurate illumination readings.
  4. Wait a few moments for the readings to stabilize on the display. The display will show soil temperature, air temperature, air humidity, and illumination.
  5. इच्छित असल्यास, दाबा धरा button to lock the displayed data for easier recording.
  6. After use, gently remove the probe from the soil.
EVTSCAN Soil Tester with probe length indicated as 22cm / 8.7in.

Figure 4: Probe length and recommended insertion depth.

Close-up of the EVTSCAN Soil Tester display showing readings for soil, air temperature, air humidity, and light.

आकृती 5: उदाample of readings on the display.

तपशील

पॅरामीटरमूल्य
Soil Temperature Range-20 ℃ to +70 ℃ (-4 ℉ to +158 ℉)
हवा तापमान श्रेणी-10 ℃ to +50 ℃ (+14 ℉ to +122 ℉)
Air Humidity Range20% ते 99% आरएच
वीज पुरवठा1 x 9V 6F22 dry battery (280mAh)
चौकशी लांबीApprox. 22 cm / 8.7 in
आयटम वजन7.7 औंस
उत्पादकईव्हीटीएसकॅन
मूलभूत कार्येAir temperature, Air humidity, Illumination display, ℃/℉ temperature switching, Data retention, Comfort display

देखभाल

  • स्वच्छता: After each use, wipe the metal probe clean with a damp cloth to remove any soil residue. Do not immerse the main body of the device in water.
  • स्टोरेज: Store the soil tester in a dry, cool place away from direct sunlight and extreme temperatures.
  • बॅटरी बदलणे: If the display becomes dim or the device does not power on, replace the 9V battery. Ensure proper disposal of old batteries according to local regulations.
  • प्रभाव टाळा: Handle the device with care to prevent damage to the probe or internal components.

समस्यानिवारण

समस्यासंभाव्य कारणउपाय
डिव्हाइस चालू होत नाही.बॅटरी संपली आहे किंवा चुकीच्या पद्धतीने स्थापित केली आहे.Check battery installation; replace with a new 9V battery if necessary.
चुकीचे किंवा चढ-उतार असलेले वाचन.Probe is not fully inserted or is dirty; soil is too dry or too wet.Ensure probe is inserted to 2/3 depth; clean probe thoroughly; ensure soil has adequate moisture for accurate readings.
प्रदर्शन अंधुक आहे.कमी बॅटरी.9 व्ही बॅटरी बदला.
Automatic shutdown occurs too quickly.Normal operation (15 minutes of inactivity).This is a power-saving feature. Turn the device back on if further use is required.

हमी आणि समर्थन

For warranty information or technical support, please refer to the contact details provided with your purchase or visit the official EVTSCAN webसाइट. खरेदीचा पुरावा म्हणून तुमची खरेदी पावती ठेवा.

© 2023 EVTSCAN. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.