BTMETER GC-01

BTMETER GC-01 न्यूक्लियर रेडिएशन डिटेक्टर वापरकर्ता मॅन्युअल

मॉडेल: GC-01

1. परिचय

This manual provides instructions for the BTMETER GC-01 Nuclear Radiation Detector. This device is designed for detecting, measuring, and monitoring radiation levels, including alpha, beta, gamma, and X-ray radiation. It is equipped with a Geiger-Müller tube for sensitive and precise measurements.

2. उत्पादन संपलेview

2.1. प्रमुख वैशिष्ट्ये

  • Equipped with an energy compensation GM tube for sensitive and accurate detection.
  • Measures Dose Equivalent Rates from 0.0-10000µSv/h and Cumulative Dose Equivalent up to 500.0mSv.
  • Detects Beta, Gamma, and X-rays.
  • Adjustable alarm settings for cumulative and current dose equivalent rates with sound, vibration, and flash light alerts.
  • Displays real-time, average, and maximum CPM readings.
  • Five selectable dosage units: µSv/h, µGy/h, mR/h, CPS, CPM.
  • Powered by a 1100mAh USB Type-C rechargeable lithium battery, providing up to 10 hours of operation.
  • Adjustable screen brightness for varied lighting conditions.

2.2. घटक

BTMETER GC-01 Nuclear Radiation Detector with USB-C cable

प्रतिमा १: समोर view of the BTMETER GC-01 Nuclear Radiation Detector, showing the display, control buttons, and included USB-C charging cable. The device is yellow and black with a clear digital screen.

BTMETER GC-01 Nuclear Radiation Detector dimensions and battery information

प्रतिमा १: Diagram illustrating the dimensions (120mm x 78mm x 27mm) and highlighting the 1100mAh rechargeable lithium battery and USB Type-C charging port. The image also shows the anti-drop and non-slip silicon material of the device casing.

२. बॉक्समध्ये काय आहे?

  • BTMETER GC-01 Nuclear Radiation Detector
  • यूएसबी टाइप-सी चार्जिंग केबल
  • वापरकर्ता मॅन्युअल (हा दस्तऐवज)

3. सेटअप

१. सुरुवातीचे चार्जिंग

Before first use, fully charge the device. Connect the supplied USB Type-C cable to the detector's charging port and to a standard USB power adapter (not included). The battery indicator on the display will show charging status. A full charge provides approximately 10 hours of continuous operation.

3.2. पॉवर चालू/बंद

  • चालू करण्यासाठी: दाबा आणि धरून ठेवा ठीक/शक्ती डिस्प्ले उजळेपर्यंत बटण दाबा.
  • पॉवर बंद करण्यासाठी: दाबा आणि धरून ठेवा ठीक/शक्ती डिस्प्ले बंद होईपर्यंत बटण.

4. ऑपरेटिंग सूचना

२. डिस्प्ले समजून घेणे

BTMETER GC-01 Nuclear Radiation Detector display showing readings and features

प्रतिमा १: The main display of the GC-01, showing real-time radiation levels, current alarm settings, cumulative alarm, and various measurement units. Icons for X, Y, β-RAY detection are visible.

The display provides real-time radiation readings, along with average and maximum values. It also shows the cumulative dose equivalent and current alarm settings.

4.2. युनिट निवड

The device supports five dosage units. To change the unit:

  1. Navigate to the 'Set Unit' option in the menu using the navigation buttons.
  2. दाबा OK निवडण्यासाठी.
  3. Choose from µSv/h, µGy/h, mR/h, CPS, or CPM.
  4. दाबा OK आपल्या निवडीची पुष्टी करण्यासाठी.
BTMETER GC-01 Nuclear Radiation Detector showing unit selection menu

प्रतिमा १: The device display showing the menu for selecting measurement units (µSv/h, µGy/h, mR/h, CPS, CPM) and demonstrating the dimmable brightness feature.

4.3. अलार्म सेटिंग्ज

The GC-01 features adjustable alarm thresholds for both current and cumulative dose equivalent rates. When a threshold is exceeded, the device can alert via sound, vibration, or flashing light.

  1. Access the 'Set Alarm' option in the menu.
  2. Adjust the desired threshold for current dose and cumulative dose using the navigation buttons.
  3. Select the preferred alarm method(s): sound, vibration, or light.
  4. दाबा OK सेटिंग्ज जतन करण्यासाठी.
BTMETER GC-01 Nuclear Radiation Detector showing adjustable alarm settings

प्रतिमा १: The device display showing the menu for adjustable alarm settings, including current alarm and cumulative alarm thresholds. Icons for sound, vibration, and LED flash light alarm modes are displayed.

4.4. Clearing Cumulative Dose

To reset the cumulative dose equivalent value, navigate to the appropriate option in the settings menu and confirm the action.

4.5. ब्राइटनेस justडजस्टमेंट

The screen brightness can be adjusted to improve visibility in various lighting conditions. Access the 'Set Disp' (Display Settings) option in the menu to modify brightness levels.

5. देखभाल

७.२. साफसफाई

मऊ, कोरड्या कापडाने उपकरण पुसून टाका. अपघर्षक क्लीनर किंवा सॉल्व्हेंट्स वापरू नका, कारण ते कव्हर खराब करू शकतात.asing किंवा डिस्प्ले.

5.2. बॅटरी काळजी

To prolong battery life, avoid fully discharging the device frequently. If storing for an extended period, charge the battery to approximately 50% and recharge every few months.

5.3. स्टोरेज

Store the detector in a cool, dry place away from direct sunlight and extreme temperatures. Keep it away from strong magnetic fields and corrosive substances.

6. समस्या निवारण

७.२. डिव्हाइस चालू होत नाही

  • Ensure the battery is charged. Connect the device to a power source using the USB-C cable and allow it to charge for at least 30 minutes before attempting to power on again.
  • पॉवर बटण योग्यरित्या दाबले आणि धरले आहे याची खात्री करा.

6.2. Readings Appear Slow or Unresponsive

  • The device updates readings every second. In environments with very low radiation levels, changes may not be immediately apparent.
  • Ensure the device is not obstructed or placed in an area that could interfere with its sensor.

३. चुकीचे वाचन

  • Ensure the device is used within its specified operating temperature and humidity ranges.
  • Avoid exposing the device to strong electromagnetic interference.
  • If persistent issues occur, contact customer support.

7. तपशील

BTMETER GC-01 Nuclear Radiation Detector professional specifications

प्रतिमा १: Detailed specifications of the GC-01, including detector type, detection rays, dose equivalent rate, cumulative dose equivalent, energy range, sensitivity, and dosage units.

डिटेक्टरEnergy Compensation GM Tube
शोध किरणांचे प्रकारγ किरण, क्ष किरण, β किरण
डोस समतुल्य दर0.0-10000µSv/h (10mSv/h)
संचयी डोस समतुल्य0.00µSv-500.0mSv
ऊर्जा श्रेणी48keV-1.5Mev ≤±30% (for 137Csγ)
संवेदनशीलता80CPM/µSv (For Co-60)
डोस युनिट्सµSv/h, µGy/h, mR/h, CPS, CPM
अलार्म पद्धतप्रकाश, कंपन, ध्वनी
बॅटरी1100mAh USB Type-C Rechargeable Lithium Battery
बॅटरी आयुष्य१० तासांपर्यंत (पूर्ण चार्ज केल्यानंतर)
परिमाण120 x 78 x 27 मिमी
वजन250 ग्रॅम

8. हमी आणि समर्थन

8.1. वॉरंटी माहिती

The BTMETER GC-01 Nuclear Radiation Detector comes with a 365-day quality warranty from the date of purchase. This warranty covers manufacturing defects and ensures the product functions as described under normal use.

8.2. तांत्रिक सहाय्य

Lifetime technical support is provided for this product. For assistance with setup, operation, troubleshooting, or any other inquiries, please contact BTMETER customer service. Refer to the product packaging or the official BTMETER webसंपर्क तपशीलांसाठी साइट.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.