इंकबर्ड आयटीसी-३०८एस

Inkbird ITC308S Temperature Controller User Manual

Model: ITC-308S

1. परिचय

The Inkbird ITC308S is a reliable and easy-to-use temperature controller designed for precise temperature management in various applications, particularly aquariums. It features dual relay outputs for both heating and cooling devices, ensuring stable temperature control. The unit includes a fully submersible probe for accurate temperature readings in liquid environments.

2. सुरक्षितता माहिती

  • Ensure the power supply matches the controller's requirements (110V for this model).
  • Do not immerse the main controller unit in water. Only the probe is submersible.
  • कोणतीही देखभाल किंवा स्थापना करण्यापूर्वी नेहमी वीज खंडित करा.
  • डिव्हाइस लहान मुले आणि पाळीव प्राण्यांपासून दूर ठेवा.
  • कोणताही भाग खराब झाल्यास डिव्हाइस वापरू नका.

3. पॅकेज सामग्री

  • ITC308S Temperature Controller Unit
  • Submersible Temperature Probe
  • Suction Cup for Probe Mounting
  • वापरकर्ता मॅन्युअल
Inkbird ITC308S package contents including controller, probe, and manual.

आकृती 3.1: The Inkbird ITC308S Temperature Controller and its included accessories, packaged in a brown box.

4. उत्पादन संपलेview

The ITC308S features a main control unit with a dual LED display, showing both the present value (PV) and set value (SV) temperatures. It has dedicated outlets for heating and cooling devices, and a detachable submersible probe for accurate temperature sensing.

Inkbird ITC308S Temperature Controller with probe and power outlets.

आकृती 4.1: ओव्हरview of the Inkbird ITC308S controller, showing the display, control buttons, power cord, and probe connection.

Close-up of the Inkbird ITC308S power strip with labeled heating and cooling outlets.

आकृती 4.2: The dual power outlets, clearly marked for 'HEATING' and 'COOLING' devices.

Close-up of the submersible temperature probe with a suction cup for mounting.

आकृती 4.3: The submersible temperature probe, designed for accurate readings in water, shown with its suction cup.

5. तपशील

वैशिष्ट्यतपशील
मॉडेलITC-308S साठी चौकशी सबमिट करा, आम्ही तुमच्याशी २४ तासांत संपर्क करू.
खंडtage120 व्होल्ट (AC)
कमाल आउटपुट लोड1200W (110V)
तापमान नियंत्रण मोडOn/Off Control (Heating and Cooling)
प्रोब प्रकारFully Submersible Aquarium Probe
डिस्प्ले प्रकारLED Dual Display
साहित्यप्लास्टिक
रंगGreen, Gray and White

४. सेटअप सूचना

  1. प्रोब कनेक्ट करा: Plug the submersible temperature probe into the designated port on the main controller unit. Use the provided suction cup to secure the probe inside your aquarium or water bath, ensuring it is fully submerged and away from direct heat sources or strong currents.
  2. हीटिंग/कूलिंग उपकरणे जोडा: Plug your heating device (e.g., aquarium heater) into the 'HEATING' outlet and your cooling device (e.g., cooling fan) into the 'COOLING' outlet on the power strip. Ensure devices are rated within the controller's maximum output load (1200W).
  3. पॉवर चालू: Plug the main power cord of the ITC308S controller into a standard 110V AC power outlet. The LED display will illuminate, showing the current temperature (PV) and the set temperature (SV).
Inkbird ITC308S submersible probe installed in an aquarium.

आकृती 6.1: The submersible probe correctly placed within an aquarium, ensuring accurate temperature measurement.

7. ऑपरेटिंग सूचना

  1. View Current Temperature (PV): The upper LED display shows the current measured temperature (Process Value).
  2. View Set Temperature (SV): The lower LED display shows the desired set temperature (Set Value).
  3. तापमान सेट करा:
    • दाबा सेट button once. The SV display will flash.
    • वापरा वर (▲) or खाली (▼) इच्छित तापमान समायोजित करण्यासाठी बटणे.
    • दाबा सेट again to confirm and save the setting, or wait a few seconds for it to save automatically.
  4. Heating/Cooling Indication: The 'HEATING' or 'COOLING' indicator lights will illuminate when the respective outlet is active.
  5. तापमान कॅलिब्रेशन: Refer to the detailed instructions in the included paper manual for advanced settings like temperature calibration, differential settings, and alarm parameters. These settings allow fine-tuning of the controller's response.
  6. अलार्मः The controller features over-temperature and sensor fault alarms. If an alarm triggers, the display will show an error code (e.g., 'HHH' for over-temperature, 'LLL' for under-temperature, 'ERR' for sensor fault) and an audible alert may sound. Address the issue promptly.

8. देखभाल

  • प्रोब साफ करणे: Regularly inspect and clean the submersible probe to prevent algae or mineral buildup, which can affect accuracy. Use a soft cloth and mild cleaning solution if necessary.
  • Controller Unit: Wipe the main controller unit with a dry, soft cloth. Do not use abrasive cleaners or immerse it in water.
  • केबल तपासणी: Periodically check all cables for any signs of wear, cuts, or damage. Replace if necessary.

9. समस्या निवारण

समस्यासंभाव्य कारणउपाय
प्रदर्शन रिक्त आहेवीजपुरवठा नाहीपॉवर कनेक्शन आणि आउटलेट तपासा.
तापमान वाचन चुकीचे आहे.Probe dirty or improperly placed; calibration neededClean probe, ensure proper submersion, perform temperature calibration.
Heating/Cooling device not turning onDevice not plugged in correctly; controller settings incorrect; device malfunctionVerify device connection to correct outlet, check set temperature and differential, test device independently.
Alarm sounds frequentlyTemperature outside set range; alarm limits too narrowAdjust set temperature or alarm high/low limits. Ensure heating/cooling devices are functioning.
'ERR' displayedसेन्सर दोषCheck probe connection. If error persists, the probe may need replacement.

10. हमी आणि समर्थन

Inkbird products are designed for reliability and performance. For warranty information, technical support, or service inquiries, please refer to the contact details provided in your product packaging or visit the official Inkbird webजागा. वॉरंटी दाव्यांसाठी तुमची खरेदी पावती ठेवा.

Ask a question about this manual